Cogging Torque: Slot–Pole, Magnet Width and Skew

Compare slot–pole combinations, ideal magnet-width cancellation points and continuous skew. Calculate harmonic attenuation and scale a measured or FEM torque amplitude.

#BLDC #cogging torque #continuous skew #harmonic analysis #magnet width #PMSM #slot-pole combinations

Cogging torque is the repeating reluctance torque felt when an unpowered permanent-magnet rotor moves past stator teeth. It matters in low-speed servos, direct drives, small generators and precision positioning. This cogging torque calculator helps engineers and students compare slot–pole combinations, magnet width and continuous axial skew before detailed magnetic analysis.

Enter the stator slot count and the total rotor pole count, including both north and south poles. The least common multiple gives the fundamental number of cogging cycles per mechanical revolution. Higher multiples are selected with the cogging harmonic number. This number differs from an electrical harmonic: the fundamental electrical field has mechanical order equal to half the pole count.

Set magnet coverage as magnet arc divided by pole pitch. The radius converts that coverage into surface arc width; the calculation steps also give the straight chord width. The width plot shows the ideal rectangular magnet-window coefficient and the corresponding fundamental field coefficient. Its dips identify candidate cancellation ratios. The widest interior fundamental null preserves the most magnet coverage among those ideal candidates. Other fundamental nulls are integer multiples of poles divided by the cogging order. A combination with no interior fundamental null is identified explicitly.

Enter skew in mechanical degrees from one end of the active stack to the other. The model averages a sinusoidal harmonic continuously along a uniform stack. The skew plot compares cogging attenuation with fundamental back-EMF retention, showing the cost of skewing the useful field. Its first zero applies to the selected harmonic. One fundamental cogging period of continuous skew cancels all integer cogging harmonics in this ideal averaging model; a smaller zero for a higher harmonic does not necessarily cancel the fundamental.

For torque in N·m, enter an unskewed Fourier peak from measurement or FEM at the selected harmonic and geometry. The default 0.2 N·m is an illustration. Changing slot–pole counts or magnet width does not rescale that baseline: replace it with the amplitude for the new geometry. The reported peak-to-peak value is twice this one harmonic's peak, not the peak-to-peak value of a complete multi-harmonic waveform. Press play to rotate the schematic and follow its instantaneous torque.

Use the SI/US switch for dimensional inputs and results. All skew and rotor angles remain explicitly mechanical. The developed axial drawing enlarges skew for clarity.

The tool assumes identical, equally spaced slots and alternating surface magnets, with uniform continuous skew. It does not solve air-gap fields, saturation, slot-opening effects, magnet fringing, eccentricity, manufacturing errors, axial end effects or stepped skew. Ideal zeros are design candidates; validate residual torque and the final magnet width using suitable field analysis and measurements. It also does not assess winding feasibility, loaded torque ripple, acoustic response or mechanical integrity.

How it is calculated

Slot–pole symmetry follows Zhu & Howe (2000), equations (1)–(4), open repository PDF pp. 3–5: Nc=lcm⁡(Q,P)N_c=\operatorname{lcm}(Q,P), selected mechanical order ν=hNc\nu=hN_c, and qualitative indicator CT=QP/NcC_T=QP/N_c. CTC_T is not used to scale torque. Slot, pole and cogging pitches are 360∘/Q360^\circ/Q, 360∘/P360^\circ/P and 360∘/Nc360^\circ/N_c.

For a rectangular magnet-energy window with coverage α\alpha, its Fourier numerator at the interacting order is Gh=∣sin⁡(πhrα)∣G_h=|\sin(\pi h r\alpha)|, where r=Nc/Pr=N_c/P. This ideal trend is derived here from the window integral. Interior fundamental zeros occur at α=j/r\alpha=j/r, j=1,…,r−1j=1,\ldots,r-1; the widest is 1−1/r1-1/r. If r=1r=1, there is no interior fundamental null. Arc and chord widths are RβmR\beta_m (angle in radians) and 2Rsin⁡(βm/2)2R\sin(\beta_m/2). The comparison field coefficient is sin⁡(πα/2)\sin(\pi\alpha/2) at fixed rectangular field plateau.

Continuous axial averaging gives Ks=sin⁡(x)/xK_s=\sin(x)/x, x=νβs/2x=\nu\beta_s/2, with Ks(0)=1K_s(0)=1 and angles converted to radians. This is Zhu & Howe equation (2). Ask=A0∣Ks∣A_{sk}=A_0|K_s|, and one sinusoid has peak-to-peak torque 2Ask2A_{sk}. Waveform phase is referenced to the stack midplane, so the signed factor is retained. Numerical waveform values are rounded at ten decimal places in the sine coefficient to remove floating-point noise at exact zeros.

The same averaging at mechanical orders P/2P/2 and 3P/23P/2 gives fundamental and third-electrical-harmonic back-EMF retention. Scuiller et al. (2020), attached manuscript pp. 6–7, independently report skew coefficients used in the reference checks. No segmentation model is imported from that paper.

Assumptions

  • Identical equally spaced stator slots and an even total number of alternating rotor poles. Surface-PM geometry with one uniformly covered magnet arc per pole.
  • The width curve assumes rectangular magnet-energy and field windows, no fringing, and unchanged field plateau. It is a normalized coefficient trend; it is not an absolute cogging torque solution.
  • The supplied unskewed amplitude belongs to the selected harmonic, slot–pole pair and magnet width. Update it whenever geometry or harmonic selection changes. The 0.2 N·m default is illustrative.
  • Uniform continuous skew and identical uncoupled axial slices. Signed skew sets handedness; amplitude retention is even in skew.
  • The rotor-angle origin is illustrative. Only one torque harmonic is animated. The axial sketch enlarges skew and is not a manufacturing drawing.

Where it applies

Use for preliminary symmetry, pole-arc and continuous-skew screening in ideal radial surface-PM machines. Magnet coverage is limited to 0.05–0.99; the full-pitch boundary is excluded because neglecting fringing would create a misleading zero. The widest ideal null is not a final magnet-width recommendation: Zhu & Howe show that fringing shifts the optimum.

A theoretical zero does not imply zero measured cogging. Manufacturing variation, eccentricity, unequal magnets, slot geometry and three-dimensional fields can introduce residual and additional harmonics. A selected higher-harmonic skew zero can leave lower harmonics. Retention is not globally monotonic with skew because sinc has sidelobes and phase reversals.

The torque result only attenuates an entered unskewed harmonic amplitude. The width trend is deliberately not multiplied into that measured/FEM baseline. Neither the slot–pole indicator nor the useful-field coefficients predict total torque, efficiency, speed ripple or vibration. Stepped/skewed segments, unequal axial lengths, saturation, end leakage, loaded torque ripple, winding feasibility and mechanical design require separate analysis.

References

  • Z. Q. Zhu and D. Howe, Influence of Design Parameters on Cogging Torque in Permanent Magnet Machines, IEEE Transactions on Energy Conversion 15(4), 407–412 (December 2000). DOI: https://doi.org/10.1109/60.900501 . Open repository edition: https://eprints.whiterose.ac.uk/id/eprint/889/1/zhuzq20.pdf (attached s1; PDF pp. 3–6).
  • F. Scuiller, F. Becker, H. Zahr and E. Semail, Design of a Bi-Harmonic 7-Phase PM Machine With Tooth-Concentrated Winding, IEEE Transactions on Energy Conversion 35(3), 1567–1576 (2020). DOI: https://doi.org/10.1109/TEC.2020.2982041 . Open author manuscript: https://hal.science/hal-02524061v1/file/L2EP_IRENAV_2020_SEMAIL.pdf (attached s2; PDF pp. 6–7).

Inputs

InputSymbolUnitDefault
Stator slots
Count all equally spaced slots around the stator.
Q12
Rotor poles (total)
Enter total north plus south poles, not pole pairs. Must be even.
P10
Magnet outer radius
Radius at which magnet arc width and circumferential skew distance are measured.
Rmm40
Magnet arc / pole pitch
Fraction of one pole pitch covered by one surface magnet. The width model neglects fringing; full-pitch magnets are outside its design range.
alpha0.8
Cogging harmonic number
1 is the fundamental cogging harmonic, at lcm(slots, poles) cycles per revolution. This is not the electrical harmonic number.
h1
Total mechanical skew
Continuous end-to-end skew across the active stack. Sign gives handedness. Do not enter electrical degrees or a stepped-rotor offset.
beta_sdeg3
Unskewed harmonic peak at this geometry
Use a measured or FEM Fourier amplitude for the selected harmonic and the same slot/pole counts and magnet width. The default 0.2 N·m is illustrative. Update this value whenever geometry changes.
A_0N*m0.2
Rotor mechanical angle
Press play to rotate the rotor and follow the selected torque harmonic. Angle is referred to the stack midplane; its phase origin is illustrative.
thetadeg1.5

Results

With the default inputs above, the calc gives:

ResultValue
Fundamental cogging cycles / revolution60
First skew zero: selected harmonic6 deg
Widest ideal fundamental width-null ratio0.8333
Magnet arc width20.1062 mm
Harmonic amplitude retained by skew0.6366
Fundamental back-EMF retained by skew0.9971
Skewed harmonic peak (entered baseline)0.1273 N·m
Single-harmonic peak-to-peak0.2546 N·m

Checked against sources

Each case below was calculated by this calc and agrees with the value from its source (within the tolerance where one is shown).

Published 9-slot / 8-pole ideal cancellation

Source: Zhu & Howe, IEEE TEC 15(4), 2000, DOI 10.1109/60.900501. Open repository PDF p. 5, Table III: Nc = 72, CT = 1, widest ideal arc ratio 0.889. PDF p. 6, section VI: first cancellation at 0.125 slot pitch (5 mechanical degrees). Values checked visually because table equations are absent from extracted text. These are ideal analytical cancellations, not measured residual torque.

Inputs: Stator slots = 9; Rotor poles (total) = 8; Total mechanical skew = 5 deg; the others as above.

ResultSourceThis calc
Fundamental cogging cycles / revolution7272
Slot–pole indicator (qualitative, not a torque multiplier)11
Widest interior ideal width null; zero means none0.8890.8889
First fundamental skew zero in slot pitches0.1250.125
Harmonic amplitude retained by skew0 ± 1 × 10⁻⁹3.898 × 10⁻¹⁷

Published 6-slot / 4-pole ideal cancellation

Source: Zhu & Howe (2000), DOI 10.1109/60.900501, open repository PDF p. 5, Table III; p. 6, section VI. Published Nc = 12, CT = 2, widest ideal arc ratio 0.667, first skew zero at half a slot pitch. Reference values are from the paper, with rounding tolerance on arc ratio; not a reproduction of its full magnetic-field torque model.

Inputs: Stator slots = 6; Rotor poles (total) = 4; Total mechanical skew = 30 deg; the others as above.

ResultSourceThis calc
Fundamental cogging cycles / revolution1212
Slot–pole indicator (qualitative, not a torque multiplier)22
Widest interior ideal width null; zero means none0.6670.6667
First fundamental skew zero in slot pitches0.50.5
Harmonic amplitude retained by skew0 ± 1 × 10⁻⁹3.898 × 10⁻¹⁷

Published 12-slot / 4-pole ideal cancellation

Source: Zhu & Howe (2000), DOI 10.1109/60.900501, open repository PDF p. 5, Table III; p. 6, section VI. Published Nc = 12, CT = 4, widest ideal arc ratio 0.667, first skew cancellation at one slot pitch. These test the published symmetry and ideal cancellation results only.

Inputs: Rotor poles (total) = 4; Total mechanical skew = 30 deg; the others as above.

ResultSourceThis calc
Fundamental cogging cycles / revolution1212
Slot–pole indicator (qualitative, not a torque multiplier)44
Widest interior ideal width null; zero means none0.6670.6667
First fundamental skew zero in slot pitches11
Harmonic amplitude retained by skew0 ± 1 × 10⁻⁹3.898 × 10⁻¹⁷

Published skew coefficient at mechanical order 28

Source: Scuiller et al., IEEE TEC (2020), DOI 10.1109/TEC.2020.2982041, attached author manuscript PDF pp. 6–7 (printed pp. 4–5). A 14-slot, 4-pole machine uses 6.43 degrees continuous skew; published mechanical-order-28 attenuation is 0.64 and electrical first/third coefficients are 0.998/0.981. Tolerances cover published rounding. Only axial averaging is transferred; their segmented-magnet width model is not reproduced.

Inputs: Stator slots = 14; Rotor poles (total) = 4; Total mechanical skew = 6.43 deg; Magnet arc / pole pitch = 0.74; the others as above.

ResultSourceThis calc
Fundamental cogging cycles / revolution2828
First skew zero: selected harmonic12.86 deg12.857 deg
Harmonic amplitude retained by skew0.64 ± 0.0050.6365
Fundamental back-EMF retained by skew0.9980.9979
Third electrical harmonic retention from skew alone0.981 ± 0.0010.9812

Published second cogging harmonic cancellation

Source: Scuiller et al. (2020), DOI 10.1109/TEC.2020.2982041, attached manuscript PDF p. 6: 6.43 degree skew cancels the second cogging harmonic; PDF p. 7 reports coefficient zero for mechanical order 56. The entered angle is rounded: the formula correctly retains about 0.000222, rather than forcing exact zero. Tolerance reflects that rounding. Segmentation itself is outside this calculator.

Inputs: Stator slots = 14; Rotor poles (total) = 4; Total mechanical skew = 6.43 deg; Cogging harmonic number = 2; Magnet arc / pole pitch = 0.74; the others as above.

ResultSourceThis calc
Selected mechanical harmonic order5656
First skew zero: selected harmonic6.43 deg6.429 deg
Harmonic amplitude retained by skew0 ± 5 × 10⁻⁴2.222 × 10⁻⁴

Related Resources

Responses

Your email address will not be published. Required fields are marked *

L ading...