Retaining Wall Calculator: Overturning, Sliding and Bearing
Check gravity and cantilever retaining walls for sliding, overturning and base bearing. Compare Rankine or Coulomb pressure, surcharge, groundwater and uplift.
This retaining wall calculator checks the external stability of a gravity or cantilever wall under static earth pressure. It is intended for engineers comparing preliminary sections, students learning soil mechanics, and people who need to understand why a wall slides, rotates or overloads its foundation. The results describe the selected cross-section and load case; they do not constitute a complete wall design.
Choose a trapezoidal gravity section with a vertical back, or a cantilever section with a uniform stem and a base slab. Enter the base width, retained height and wall dimensions. Height is measured from the underside of the base to the ground at the pressure plane. For a cantilever wall, that plane extends vertically through the heel, so sloping backfill changes both the stem height and the soil weight carried above the footing.
Choose Rankine or Coulomb active pressure and enter drained soil properties. The lateral earth pressure calculator separates effective soil pressure, uniform surcharge and water pressure, then locates their combined horizontal resultant. Rankine directs its soil thrust parallel to a sloping backfill surface. Coulomb uses the selected interface friction angle. Both methods assume that the wall can move enough to develop active pressure.
For groundwater, use level backfill and enter the water elevation above the base underside. The calculation subtracts water from saturated soil unit weight and adds hydrostatic lateral pressure separately. Base uplift varies linearly from a drained toe to the selected fraction of groundwater head at the heel. Test a credible high-water case as well as normal drainage conditions.
The retaining wall stability check reports sliding and overturning factors, base eccentricity, the middle-third limit, and effective bearing pressures. If the resultant leaves the middle third, the base diagram changes to a compression-only triangular distribution. That result remains a failed full-contact screening check. A resultant outside the base has no compression-only equilibrium.
Use site-specific base friction and allowable bearing pressure. The initial factors of 1.5 for sliding and 2.0 for overturning are editable screening targets. Compare surcharge cases with and without vertical heel weight: omitting favorable weight may govern stability, while including it can govern bearing. The pressure and surcharge charts help explain which load controls.
The tool excludes global stability, earthquakes, reinforcement design, settlement and construction sequencing. Walls above about 1.2 m usually need an engineer and a permit, with local requirements controlling. Shorter walls supporting traffic, buildings or steep slopes can also need professional design. Installation and excavation must be carried out by qualified people using an appropriate design.
How it is calculated
Loads and the pressure plane
A unit length of wall is analyzed in drained effective stress. The gravity wall has a vertical back and a tapered front. The cantilever has a uniform stem, a horizontal footing, and a vertical pressure plane at the heel. Height H runs from the base underside to ground at that plane; stem height is H minus footing thickness and the rise of the backfill over the heel.
Mass densities convert to unit weights using g = 9.81 m/s². The active coefficient is the total thrust coefficient. Rankine uses the sloping-backfill expression and directs thrust parallel to the slope; Coulomb uses the vertical-face special case of FHWA GEC 6 Eq. 6-2, with thrust inclined downward by the chosen interface angle. A cantilever Coulomb analysis follows the virtual heel-plane convention illustrated by MnDOT (attached pp. 100–102); interface friction there describes soil interaction.
Earth, surcharge and groundwater
For level backfill with groundwater height h_w, submerged unit weight is γ′ = γ_sat − γ_w. Integration of effective stress gives soil thrust K_a[γH² + (γ′ − γ)h_w²]/2 and its moment K_a[γH³ + (γ′ − γ)h_w³]/6, before resolving horizontally. Uniform vertical surcharge adds K_a q H at H/2; water adds γ_w h_w²/2 at h_w/3, horizontally. These integrations and the wall centroids are derived here from statics. USACE EM 1110-2-2502 (1989), Chapter 3, supplies the classical framework; its superseding 2022 hydraulic-wall guidance is a separate, broader design procedure.
Equilibrium and bearing
Wall and heel-soil weights, credited permanent surcharge and downward earth thrust stabilize the wall. Uplift varies linearly from zero at the drained toe to r_u γ_w h_w at the heel. Its resultant is U = r_u γ_w h_w B/2 at 2B/3 from the toe.
Sliding FS = μN/P_h, with N = total downward force − U. Overturning FS = stabilizing moments / overturning moments about the toe; uplift belongs in the overturning denominator. The base resultant is x = (M_resist − M_drive)/N and e = B/2 − x.
For |e| ≤ B/6, effective contact pressure is N/B(1 ± 6e/B). Outside that range, a compression-only triangle has contact width 3(B/2 − |e|) and peak pressure 2N/contact width. This is a linear contact-stress screening model, not a bearing-capacity solution. Compare its peak with a compatible site-specific allowable stress. See FHWA GEC 6, attached pp. 124–125, for the distinction between a linear contact distribution and an effective-area capacity calculation. Force and moment closure are checked for both contact regimes. Arrows in the section are symbolic; the separate pressure envelope is normalized to its own maximum.
Assumptions
- Homogeneous cohesionless backfill, constant drained friction angle, planar ground, and enough wall movement to mobilize active pressure.
- A horizontal base on soil, with no anchorage, shear key, base adhesion or passive resistance. Base friction is a separate site-specific input.
- Groundwater is horizontal and permitted only with level backfill; no front-face water, ponding above ground, seepage gradients in the backfill or rapid drawdown.
- The uplift model assumes a drained toe. Lowering its fraction requires evidence from drainage or seepage analysis; it is not an automatic drainage credit.
- Soil over the cantilever heel uses total moist/saturated weight. Earth thrust is applied at the virtual heel plane; top-of-stem lateral design is not calculated.
- Lateral surcharge always acts over the full active wedge. The heel-weight setting defines the selected vertical load case: excluded heel weight is favorable for sliding/overturning screening but may be unfavorable for bearing. Check both settings when a surcharge can act over the heel.
- The sketch uses a common geometry scale and a separate relative lateral-pressure scale. H includes the base thickness. Positive eccentricity is toward the toe.
Where it applies
Use for preliminary external stability checks and teaching, not construction authorization. Default targets (sliding 1.5 and overturning 2.0) are editable screening assumptions, not universal requirements. The allowable bearing pressure must come from a geotechnical assessment and must be compatible with effective contact stress, settlement, base inclination and the selected load case. Do not divide an allowable pressure by another bearing safety factor.
Global/slope stability, seismic loading, structural reinforcement, stem and footing bending/shear, masonry/block interlock, settlement, internal wall failure, frost, scour, layered/cohesive/expansive soil and construction-stage loads are outside scope. Restrained basement walls may require at-rest pressure. A partial-contact result fails this tool's middle-third screening criterion even if its calculated peak pressure is below the allowance; separation can also change seepage and uplift.
Walls taller than about 1.2 m (4 ft) usually need an engineer and a permit; local thresholds vary, and surcharges or nearby structures may require review at smaller heights. Confirm local requirements. Installation and excavation work belongs to qualified people following an engineered plan.
This is a classical unfactored service-load calculation. It does not implement AASHTO LRFD or the complete USACE hydraulic-wall procedure. Source editions are FHWA GEC 6 (2002), the MnDOT worked example (July 2016), and the classical USACE manual (1989, superseded in 2022). Check against the standard and local rules in force; source/edition review date: 26 October 2026.
References
- FHWA-SA-02-054, GEC No. 6, Shallow Foundations (September 2002), §§4.4.2, 6.3.2 and 6.4; attached s3 pp. 50, 120–125. https://www.fhwa.dot.gov/engineering/geotech/pubs/010943.pdf
- USACE EM 1110-2-2502, Retaining and Flood Walls (29 September 1989), Chapters 3–4; superseded classical reference. https://www.publications.usace.army.mil/portals/76/publications/engineermanuals/em_1110-2-2502.pdf
- USACE EM 1110-2-2502, Floodwalls and Other Hydraulic Retaining Walls (1 August 2022); current broader hydraulic-wall guidance, not fully implemented. https://www.publications.usace.army.mil/Portals/76/Users/182/86/2486/EM%201110-2-2502.pdf
- MnDOT LRFD Bridge Design Manual, section 11.4.2 (July 2016), pp. 11-100–102; Coulomb load benchmark only, not its LRFD design procedure. https://www.dot.state.mn.us/bridge/pdf/lrfdmanual/section11.pdf
- SkyCiv, Retaining Wall Sliding Calculation Example, accessed 26 October 2026; published cantilever reference, with documented unit and base-weight typos. https://skyciv.com/docs/skyciv-retaining-wall/articles/retaining-wall-sliding-calculation-example/
- Richard P. Weber, Retaining Walls for Non-Geotechnical Engineers, CED course G02-013, printed pp. 8–10, Figure 3 worked example. https://www.cedengineering.com/userfiles/G02-013%20-%20Retaining%20Walls%20for%20Non-Geotechnical%20Engineers%20-%20US.pdf
Inputs
| Input | Symbol | Unit | Default |
|---|---|---|---|
| Wall section | wall_type | Cantilever — uniform stem | |
| Active pressure method | pressure_method | Rankine | |
| Retained height at pressure plane From underside of base to ground at the heel; includes footing thickness. | H | m | 3.5 |
| Base width Toe at x = 0; heel at x = B. | B | m | 2.6 |
| Footing thickness Cantilever wall only. | t_base | m | 0.35 |
| Toe projection From the toe to the front of the stem. | a_toe | m | 0.65 |
| Stem thickness Uniform vertical stem. | t_stem | m | 0.3 |
| Gravity wall top width Back face is vertical; front face slopes from toe to crest. | b_top | m | 0.6 |
| Wall mass density Concrete is commonly near 2400 kg/m³. Unit weight is density × gravity; use a measured or specified value. | rho_wall | kg/m^3 | 2400 |
| Effective soil friction angle Drained strength of homogeneous cohesionless backfill. | phi_s | deg | 30 |
| Backfill slope Ground rises away from wall; measured above horizontal. Use level backfill for water cases. | beta_s | deg | 0 |
| Interface friction angle Coulomb force inclination. At a cantilever heel this describes the virtual soil plane, not concrete friction. | delta_s | deg | 20 |
| Moist backfill mass density Total mass density above groundwater. For unit weight in kN/m³, divide by 0.00981. | rho_soil | kg/m^3 | 1800 |
| Uniform vertical surcharge Over the full active wedge; per horizontal projected ground area. | q_sur | kPa | 10 |
| Surcharge weight on heel Lateral surcharge always acts. Check both heel-weight settings: exclusion may govern sliding/overturning; inclusion can govern bearing. | surcharge_credit | Exclude heel weight (stability load case) | |
| Water level above base underside Level groundwater behind wall; no water on exposed face. Set zero for dry or drained backfill. | h_water | m | 0 |
| Uplift fraction: heel head to drained toe Linear base uplift, zero at toe and this fraction of groundwater head at heel. Use 1 unless drainage is justified. | r_uplift | 1 | |
| Saturated backfill mass density Total saturated mass density. Submerged unit weight is calculated after subtracting water. | rho_sat | kg/m^3 | 2000 |
| Base friction coefficient Site-specific wall/foundation interface value. Passive resistance and cohesion are excluded. | mu_base | 0.55 | |
| Allowable effective bearing pressure Site-specific service allowable pressure, compatible with effective base contact stress; already includes geotechnical safety margin. | q_allow | kPa | 200 |
| Required overturning factor Editable screening target, not a universal code requirement. | FS_ot_req | 2 | |
| Required sliding factor Editable screening target; check rules in force. | FS_sl_req | 1.5 |
Results
With the default inputs above, the calc gives:
| Result | Value |
|---|---|
| External stability screening | Meets selected external checks |
| Sliding factor of safety | 1.561 |
| Overturning factor of safety | 3.338 |
| Maximum effective bearing pressure | 78.7 kPa |
| Minimum effective bearing pressure | 25.5 kPa |
| Eccentricity (+ toward toe) | 0.222 m |
| Middle-third limit, B / 6 | 0.433 m |
| Base contact | Full contact |
| Horizontal driving force per wall length | 47.72 kN/m |
| Active coefficient (total thrust) | 0.3333 |
| Bearing demand / allowable | 0.394 |
Checked against sources
Each case below was calculated by this calc and agrees with the value from its source (within the tolerance where one is shown).
Published cantilever wall: weights, earth loads and sliding
Source: SkyCiv, Retaining Wall Sliding Calculation Example (accessed 2026-10-26), input data and calculation through final FS = 1.556. https://skyciv.com/docs/skyciv-retaining-wall/articles/retaining-wall-sliding-calculation-example/ . Source prints surcharge as kN/m, but it is a pressure (kPa) as its multiplication by heel width and equivalent soil-height calculation demonstrate. Exact trigonometry retained; tolerance allows the source's rounded Ka = 0.271. The printed W_base = 18.855 kN/m is an arithmetic typo: 23.58 × 0.381 × 2.210 = 19.8546 kN/m. The published final total 135.12 kN/m and FS 1.556 use the correct base weight; that erroneous intermediate is not used as a reference.
Inputs: Retained height at pressure plane = 3.505 m; Base width = 2.21 m; Footing thickness = 0.381 m; Toe projection = 0.686 m; Stem thickness = 0.305 m; Effective soil friction angle = 35 deg; Uniform vertical surcharge = 17.237 kPa; Surcharge weight on heel = Include permanent surcharge weight; Wall mass density = 2,404 kg/m³; Moist backfill mass density = 1,922 kg/m³; the others as above.
| Result | Source | This calc |
|---|---|---|
| Active coefficient (total thrust) | 0.271 | 0.271 |
| Weight of stem or gravity wall rectangle | 22.467 kN/m | 22.467 kN/m |
| Total soil weight over heel | 71.784 kN/m | 71.784 kN/m |
| Credited vertical surcharge on heel | 21.012 kN/m | 21.012 kN/m |
| Horizontal driving force per wall length | 47.749 kN/m | 47.749 kN/m |
| Sliding factor of safety | 1.556 | 1.556 |
MnDOT published Coulomb coefficient and earth-force components
Source: MnDOT LRFD Bridge Design Manual, July 2016, section 11.4.2, printed pp. 11-100–102 (attached pages 100–102). Independent earth-pressure subcase: H = 15.16 ft, gamma = 0.120 kip/ft³, phi = 35°, delta = 23.33°, beta = 9.46°, Ka = 0.273, total P = 3.77 kip/ft, horizontal 3.46 kip/ft and vertical 1.49 kip/ft. Geometry is a gravity section only to isolate this published load benchmark; it does not reproduce the complete LRFD wall. Converted with 1 kip/ft = 14.5939029372 kN/m. Published 'ksi' beside 0.497 on p.101 is a unit typo; it is ksf. Tolerances allow published rounding.
Inputs: Wall section = Gravity — vertical back, tapered front; Active pressure method = Coulomb; Retained height at pressure plane = 4.621 m; Base width = 4 m; Gravity wall top width = 1 m; Effective soil friction angle = 35 deg; Interface friction angle = 23.33 deg; Backfill slope = 9.46 deg; Uniform vertical surcharge = 0 kPa; Wall mass density = 2,446 kg/m³; Moist backfill mass density = 1,922 kg/m³; the others as above.
| Result | Source | This calc |
|---|---|---|
| Active coefficient (total thrust) | 0.273 | 0.2729 |
| Effective soil thrust magnitude | 55.019 ± 0.15 kN/m | 54.912 kN/m |
| Horizontal driving force per wall length | 50.495 ± 0.1 kN/m | 50.422 kN/m |
| Downward component of earth and surcharge thrust | 21.745 ± 0.1 kN/m | 21.747 kN/m |
Weber published cantilever: moments, eccentricity and bearing
Source: Richard P. Weber, Retaining Walls for Non-Geotechnical Engineers, CED G02-013, printed pp. 8–10 (PDF pp. 9–11), worked example Figure 3. https://www.cedengineering.com/userfiles/G02-013%20-%20Retaining%20Walls%20for%20Non-Geotechnical%20Engineers%20-%20US.pdf . Published N = 6100 lb/ft, resisting moment = 20500 ft-lb/ft, FSot = 4.4, FSsl = 1.58, e = 0.4 ft, qmax = 1423.4 psf, qmin = 610 psf. The source rounds Ka to 0.307 and eccentricity to 0.4 ft before calculating pressure; this tool retains precision. Tolerances allow those documented rounding effects.
Inputs: Retained height at pressure plane = 2.743 m; Base width = 1.829 m; Footing thickness = 0.3048 m; Toe projection = 0.3048 m; Stem thickness = 0.3048 m; Wall mass density = 2,402 kg/m³; Moist backfill mass density = 2,002 kg/m³; Effective soil friction angle = 32 deg; Uniform vertical surcharge = 0 kPa; Base friction coefficient = 0.404; the others as above.
| Result | Source | This calc |
|---|---|---|
| Effective compressive base force | 89.023 kN/m | 89.023 kN/m |
| Total stabilizing moment about toe | 91.189 kN·m/m | 91.189 kN·m/m |
| Overturning factor of safety | 4.4 ± 0.02 | 4.393 |
| Sliding factor of safety | 1.58 ± 0.01 | 1.584 |
| Eccentricity (+ toward toe) | 0.1219 ± 0.002 m | 0.1232 m |
| Maximum effective bearing pressure | 68.153 ± 0.3 kPa | 68.361 kPa |
| Minimum effective bearing pressure | 29.207 ± 0.3 kPa | 28.996 kPa |