Wall Sound Insulation Calculator: Mass Law, Double Walls & Leaks
Estimate wall transmission loss, mass–air–mass resonance, coincidence dips and the effect of openings. Compare single and separated double leaves with approximate STC/Rw ratings.
Use this wall sound insulation calculator to estimate how much airborne sound a partition stops at different frequencies. It is intended for studio builders, engineers and students comparing wall assemblies. The plots show the effect of air-spring resonance, coincidence and open bypasses. Use the STC and Rw estimates as screening summaries of the spectrum.
Choose a single leaf or a separated double leaf. Set each leaf’s effective density and total solid material thickness. Their product is its surface mass. For example, a 12.5 mm board with a surface mass of 10 kg/m² has an effective density of 800 kg/m³. Multiple boards fixed to one frame form one leaf. Use the effective critical frequency of that leaf, especially if it contains bonded layers.
For a double wall, enter the distance between the inner leaf faces. The cavity depth includes the two frame depths, any space between them and any insulation in those spaces. The model assumes independent frames and a fibrous absorber. Under Details, enable room air temperature and pressure to use your local conditions. Finer frequency sampling gives a closer look at narrow resonance dips.
Enter the gross partition area and any equivalent open area. A uniform gap has an area equal to its width times its length. The model treats that opening as an unobstructed path through the whole assembly. Compare the sealed and open-wall curves to see when the bypass controls the result. The wall STC calculator rates the estimated 125–4000 Hz bands. The Rw estimator uses 100–3150 Hz. Inspect the low-frequency curve for bass, drums or machinery.
Open Details for three optional comparisons. Largest opening for a target gives an equivalent area, a uniform width and a signed area margin at the inspection frequency. If a door or window is included, the allowance uses the insert’s area, tested TL and selected frequency basis. A negative margin means the opening exceeds the target allowance. Wall B adds a 12.5 mm board and 10 kg/m² to leaf 1 by default. Check the remaining depth and compare the TL in the 63, 125 and 500 Hz bands. Wall B inherits Wall A’s critical frequencies unless you override them. Treat the 63 Hz gain as a sensitivity estimate near resonance.
For Door or window, enter the tested TL of the installed assembly, including its frame and seals. The default comparison uses the third-octave band nearest to the inspection frequency. Select single-frequency mode when you have a tested narrowband TL at that frequency. The wall, insert and any separate opening are combined by transmitted power. The power shares show which path carries most sound.
The fixed NRC benchmark shows how the model compares with laboratory data. Field performance also depends on supports, workmanship and surrounding rooms. Shared studs, ducts, flanking paths, empty cavities, triple leaves and thick masonry require other models or measured data. This calculator provides estimates for design comparisons. Use tested ratings for specifications and check against the standard in force. Installation work belongs to a qualified person.
How it is calculated
Surface mass is . The published default uses reference air density of 1.2 kg/m³ and sound speed of 343 m/s. Enable room air temperature and pressure under Details to calculate both dry-air properties with CoolProp. The acoustic impedance is and the adiabatic bulk modulus is .
Single leaf
Use the high-mass approximation to the field-incidence mass law, . It follows by keeping the dominant mass term in Ashmore et al. (2015), p. 3, Eq. 4, and corresponds to the rounded SI form in Ballagh (2004), Eq. 1. Use the dimensionless ratio to identify the low-mass limit. The tool warns when at the low end of the modeled mass-law range. The cutoff flags use of the asymptote in a region where a finite-angle limp-leaf model can differ appreciably. At and above the critical frequency use Ashmore et al., Eq. 6, . Interpolate in log frequency from to .
Separated double leaf
The resonance is . In the middle and upper regimes, Sharp's absorbent-cavity correction to the sum of the leaf TLs is , with . This is the intersection of the two published asymptotes reproduced in Ballagh (2004), Eqs. 5–6. The commonly quoted is a rounded transition.
Below use a loaded normal-incidence network with series normalized leaf impedances and shunt cavity admittance . Form its transfer matrix, whose entries are , , and . With unit incident pressure, and . The reflected, transmitted and dissipated fractions are , and . The checks sum these raw fractions, including a lossless case. Field estimates subtract 5 dB from the network TL and clip TL at zero. From to , blend transmitted power into Sharp's asymptote using a cubic smoothstep in log frequency. The network and this blend extend Sharp's asymptotes through the resonance.
Openings, bands and ratings
Use . Add area-weighted transmitted power for the wall, an optional tested insert and the unobstructed bypass (), following ASHRAE Fundamentals, Ch. 8, Eq. 41. For an insert area fraction , first compute closed-partition transmission . An opening replaces opaque wall area, so its limiting fraction is , bounded by the available area fraction . A target above the closed-partition TL is infeasible. With an insert, use the same third-octave or single-frequency basis for both the opening allowance and the composite TL.
Third-octave TL averages transmitted power at nine log-frequency midpoints per band before conversion to dB. The default spectrum uses 181 log-spaced points from 50 to 5000 Hz. Finer frequency sampling uses IEC 61260-1:2014 exact base-10 centres and edges. The centre frequencies are Hz with integer , and the edge factors relative to the centre are . The plots and tables keep nominal band labels. Finer mode adds plot points around each active air-spring resonance and uses 96 band midpoints at its default setting or 192 for the fixed NRC benchmark. Compare Wall A and Wall B using integrated band TL and the same opening. In insert band mode, use the opaque wall TL in the band nearest to the inspection frequency. In single-frequency mode, use a tested insert TL at the inspection frequency itself. Compute each path’s share by dividing its area-weighted transmission by the total.
STC uses 125–4000 Hz and Rw uses 100–3150 Hz. Before fitting, round STC input bands to the nearest whole dB (ASTM E413-22 §5.2) and round Rw input bands to 0.1 dB (ISO 717-1:2020 §4.4). Fit the highest integer contour with total deficit up to 32 dB. STC also limits any one band's deficit to 8 dB. Read both contours at 500 Hz.
Assumptions
- The fixed NRC benchmark uses the reference air properties by default. With the room air option enabled, the benchmark uses dry air at 20 °C and 101.325 kPa independently of the entered conditions.
- Each leaf is broad and thin. Enter an effective coincidence frequency for the complete leaf. Surface mass alone does not establish bending stiffness.
- The double-leaf model assumes independent supports and fibrous cavity absorption. The air-spring loss factor is a sensitivity input. No absorber product, airflow resistivity or mounting-specific damping is inferred.
- The area-weighted transmission model assumes uniform incident sound power per area and separate wall, insert and equivalent open paths. Enter only openings outside leakage already included in the insert test.
Where it applies
Use the model for preliminary design in the plotted 50–5000 Hz range. The end third-octave bands extend beyond those limits. Enable finer frequency sampling to better resolve a narrow resonance dip on the spectrum and in the band averages. For very light leaves at low frequencies, the mass-law asymptote can clip the predicted TL to zero. For example, at 200 Hz a 1 kg/m² limp leaf gives about 2.9 dB when the angle-dependent transmission is averaged to 85°, compared with 0 dB from the clipped approximation. Use measured TL when the low-mass warning appears. Obtain tested assembly ratings for specifications and check against the standard in force.
The 63 Hz Wall B gain is a sensitivity estimate. NRC IR-761 measured +2.8 dB in the matched TL-93-270 / TL-93-271 pair (printed pp. 319 and 339) after adding one 10.2 kg/m² board. This model gives +8.54 dB at default sampling and air settings under the same mass and depth inputs. The air-spring damping and critical frequencies for that prediction are screening assumptions. No coefficients were fitted to the pair. The 6 dB tolerance in that check acknowledges the 5.74 dB overprediction. At 125 and 500 Hz the corresponding measured gains were +4.3 and +4.8 dB.
At default settings, the fixed NRC TL-93-279 model is 13.9 dB below the measurement at 63 Hz (4.3 versus 18.2 dB) and 9.3 dB above it at 2500 Hz (69.1 versus 59.8 dB). The modeled STC is 52 and the measured STC is 53. The spot-check tolerances for TL-93-279 and TL-93-262 apply only to the 125 and 500 Hz bands and the STC ratings tested. See NRC IR-761, printed pp. 316 and 330. The 30 dB insert default is a placeholder for tested data.
The model excludes room-to-room level difference, flanking transmission, shared supports, resilient mounts, empty cavities, slit diffraction, ducts, triple leaves and heavy masonry shear waves. The opening bar shows the equivalent fraction of total wall area. Thin single leaves have a minimum display width in the section. Installation work belongs to a qualified person.
References
- B. H. Sharp (1978), Prediction Methods for the Sound Transmission of Building Elements, Noise Control Engineering 11(2), 53–63. https://doi.org/10.3397/1.2832099
- K. O. Ballagh (2004), Accuracy of Prediction Methods for Sound Transmission Loss, Inter-Noise 2004, pp.2–3. https://static1.squarespace.com/static/62b943270a6d6d4fa1970dee/t/66862bbb9374252e7a84f6d9/1720069056129/10_accuracy_of_prediction_methods_for_sound_transmission_loss.pdf
- AAS Acoustics 2015 paper p74, Sound insulation of vacuum insulated glazing, PDF p.3, Sharp single-leaf equations. https://acoustics.asn.au/conference_proceedings/AAS2015/papers/p74.pdf
- R. E. Halliwell et al. (1998), Gypsum Board Walls: Transmission Loss Data, NRC IRC-IR-761, printed pp.17, 316 and 330. https://doi.org/10.4224/20331556
- ASHRAE Handbook—Fundamentals (2025), Chapter 8, Eq.41 and the 40 dB wall/1% opening example. https://handbook.ashrae.org/Handbooks/F25/IP/F25_Ch08/F25_Ch08_ip.aspx
- ASTM E413-22, Classification for Rating Sound Insulation, §5.2 band rounding and contour-fitting procedure. https://store.astm.org/e0413-22.html
- ISO 717-1:2020, Acoustics—Rating of sound insulation, Part 1, §4.4 band rounding before comparison (printed p.4). https://cdn.standards.iteh.ai/samples/77435/7e658360f54d4ddc9e6f23c0a1e7d41e/ISO-717-1-2020.pdf
- I. H. Bell et al. (2014), CoolProp thermophysical property library. https://doi.org/10.1021/ie4033999
- IEC 61260-1:2014, Electroacoustics—Octave-band and fractional-octave-band filters, Part 1, §§5.2–5.6. https://preview.sist.si/sist-preview/13383/3c4ae3e762b540cc8111744cb8f0ae8e/IEC-61260-1-2014.pdf
- A. London (1949), Transmission of Reverberant Sound Through Single Walls, NBS RP 1998. https://doi.org/10.6028/jres.042.053
Inputs
| Input | Symbol | Unit | Default |
|---|---|---|---|
| Wall model “Separated double leaf, absorbent cavity” assumes separate frames. | construction | Separated double leaf, absorbent cavity | |
| Leaf 1 effective density If surface mass is known, divide it by total leaf thickness. | rho_1 | kg/m^3 | 800 |
| Leaf 1 total material thickness | t_1 | mm | 12.5 |
| Leaf 1 critical frequency Enter the measured or effective coincidence frequency of this leaf. | f_c1 | Hz | 3000 |
| Leaf 2 effective density If surface mass is known, divide it by total leaf thickness. | rho_2 | kg/m^3 | 800 |
| Leaf 2 total material thickness | t_2 | mm | 12.5 |
| Leaf 2 critical frequency Enter the measured or effective coincidence frequency of this leaf. | f_c2 | Hz | 3000 |
| Leaf loss factor Effective structural damping of the leaf material. | eta_leaf | 0.03 | |
| Face-to-face cavity depth Measure between the inner leaf faces, including insulation. | d_gap | mm | 205 |
| Air-spring loss factor Assumed damping near the air-spring resonance. | eta_cavity | 0.15 | |
| Total partition area Use gross area, including the door or window and any openings. | A_wall | m^2 | 10 |
| Total equivalent open area For an unobstructed gap, enter its length × width. | A_leak | cm^2 | 10 |
| Inspect frequency Sets where you inspect TL and evaluate the optional opening limit. | f_probe | Hz | 500 |
| Calculate opening limit | check_opening_target | false | |
| Target transmission loss Uses the inspection frequency or the selected door or window basis. | R_target | dB | 40 |
| Uniform gap length | L_gap | m | 1 |
| Compare Wall B | compare_wall_b | false | |
| Added thickness on leaf 1 | t_board | mm | 12.5 |
| Added board density Divide the board’s mass per unit area by its thickness to obtain its effective density. | rho_board | kg/m^3 | 800 |
| Maximum wall depth | D_budget | mm | 250 |
| Set Wall B critical frequencies Wall B uses Wall A’s critical frequencies until you enable this. | edit_b_critical | false | |
| Wall B leaf 1 critical frequency | fc_B1 | Hz | 3000 |
| Wall B leaf 2 critical frequency | fc_B2 | Hz | 3000 |
| Include a door or window | include_insert | false | |
| Door or window area Use the area of the tested assembly, including its frame. | A_insert | m^2 | 2 |
| Test data frequency basis | insert_mode | Third-octave band | |
| Tested door or window TL Enter the tested TL for the frequency basis shown in the results. | R_insert | dB | 30 |
| Use room air temperature and pressure | use_air_state | false | |
| Room air temperature | T_air | °C | 20 |
| Absolute air pressure | p_air | kPa | 101.325 |
| Use finer frequency sampling Refines the plots around resonance and uses more samples in each third-octave band. | fine_band_resolution | false | |
| Integration samples per third octave | n_band | 96 |
Results
With the default inputs above, the calc gives:
| Result | Value |
|---|---|
| STC estimate · with opening | 40 |
| Rw estimate · with opening | 40 dB |
| TL at inspect frequency · with opening | 39.9 dB |
| Loss caused by opening at inspect frequency | 19.3 dB |
| Sealed-wall STC estimate | 52 |
| Sealed-wall Rw estimate | 53 dB |
| Resonance | 59.1 Hz mass–air–mass resonance |
| Open-area limit | 40 dB opening ceiling |
| Maximum equivalent opening | 9.88 cm² |
| Maximum uniform gap width | 0.988 mm |
| Opening area remaining | -0.12 cm² |
| Wall B total depth | 242.5 mm |
| Wall B depth remaining | 7.5 mm |
| Wall B mass–air–mass resonance | 51.2 Hz |
| Door or window comparison band or frequency | 500 Hz third-octave band |
| Partition TL with door or window | 35.2 dB |
| Transmitted power through opaque wall | 0.3 % |
| Transmitted power through door or window | 66.4 % |
| Transmitted power through opening | 33.2 % |
It also shows: Wall B − A · 63 Hz band (sensitivity), dB; Wall B − A · 125 Hz band, dB; Wall B − A · 500 Hz band, dB.
Checked against sources
Each case below was calculated by this calc and agrees with the value from its source (within the tolerance where one is shown).
NRC TL-93-279: sealed separate 13 mm gypsum leaves
Source: NRC IR-761 (1998), TL-93-279, printed p.316 / PDF p.319. Two 10 kg/m² leaves; 90+25+90 mm cavity; one 90 mm glass-fibre batt. 3000 Hz and damping are independent screening assumptions. Model checked within 3 dB only at these bands and STC; the comparison chart retains the larger low-frequency/coincidence mismatch.
Inputs: Total equivalent open area = 0 cm²; the others as above.
| Result | Source | This calc |
|---|---|---|
| Sealed third-octave TL at 125 Hz | 29 ± 3 dB | 28.024 dB |
| Sealed third-octave TL at 500 Hz | 60 ± 3 dB | 59.114 dB |
| Sealed-wall STC estimate | 53 ± 3 | 52 |
NRC TL-93-262: sealed separate 16 mm gypsum leaves
Source: NRC IR-761 (1998), TL-93-262, printed p.330 / PDF p.333. Surface masses 11.6 and 11.4 kg/m²; cavity 205 mm with two 65 mm glass-fibre batts. 2500 Hz is an assumed critical frequency for 16 mm gypsum, not a fitted NRC property. The wider 5 dB low-band/STC tolerance acknowledges unmodeled fill and finite-panel effects.
Inputs: Leaf 1 critical frequency = 2,500 Hz; Leaf 2 critical frequency = 2,500 Hz; Total equivalent open area = 0 cm²; Leaf 1 effective density = 725 kg/m³; Leaf 1 total material thickness = 16 mm; Leaf 2 effective density = 712.5 kg/m³; Leaf 2 total material thickness = 16 mm; the others as above.
| Result | Source | This calc |
|---|---|---|
| Sealed third-octave TL at 125 Hz | 34.4 ± 5 dB | 30.446 dB |
| Sealed third-octave TL at 500 Hz | 61.2 ± 3 dB | 61.541 dB |
| Sealed-wall STC estimate | 58 ± 5 | 54 |
Rating algorithm: measured NRC TL-93-279 spectrum
Source: NRC IR-761, TL-93-279 published STC 53. This verifies contour fitting from the independent measured spectrum, not prediction accuracy.
Inputs: the default inputs above.
| Result | Source | This calc |
|---|---|---|
| STC computed from NRC TL-93-279 measured data | 53 | 53 |
Rating algorithm: measured NRC TL-93-262 spectrum
Source: NRC IR-761, TL-93-262 published STC 58. This verifies contour fitting from the independent measured spectrum.
Inputs: the default inputs above.
| Result | Source | This calc |
|---|---|---|
| STC computed from NRC TL-93-262 measured data | 58 | 58 |
ASHRAE: 40 dB wall with 1% open area
Source: ASHRAE Handbook—Fundamentals (2025), Ch.8 Eq.41 worked example: 40 dB partition with 1% open area gives 20 dB overall. The exact energy sum is 19.957 dB; tolerance covers the published rounding. https://handbook.ashrae.org/Handbooks/F25/IP/F25_Ch08/F25_Ch08_ip.aspx
Inputs: the default inputs above.
| Result | Source | This calc |
|---|---|---|
| Published leakage benchmark: 40 dB wall, 1% open | 20 ± 0.05 dB | 19.957 dB |
Review regression: 7 cm² opening gives STC 42
Source: Independent reviewer boundary example supplied with this review: default wall with A_leak = 7 cm² must give STC 42 after integer band rounding. Rounding rule: ASTM E413-22 §5.2, https://store.astm.org/e0413-22.html. This is a contour-rounding regression, not a published laboratory wall result.
Inputs: Total equivalent open area = 7 cm²; the others as above.
| Result | Source | This calc |
|---|---|---|
| STC estimate · with opening | 42 | 42 |
Review regression: 7.2 cm² opening gives Rw 41 dB
Source: Independent reviewer boundary example supplied with this review: default wall with A_leak = 7.2 cm² must give Rw 41 dB after rounding bands to 0.1 dB. Rule: ISO 717-1:2020 §4.4, printed p.4 / attached preview p.10. This is a contour-rounding regression, not a laboratory measurement.
Inputs: Total equivalent open area = 7.2 cm²; the others as above.
| Result | Source | This calc |
|---|---|---|
| Rw estimate · with opening | 41 dB | 41 dB |
NRC TL-93-270 to TL-93-271 added-board gain
Source: NRC IR-761, TL-93-270 and TL-93-271, printed pp.319 and 339 (PDF pp.322 and 342). One 10.2 kg/m² board was added to a 205 mm cavity assembly with two 10.2 kg/m² leaves. Measured TL changes at 63, 125 and 500 Hz were +2.8, +4.3 and +4.8 dB. The 63 Hz tolerance explicitly covers the documented 5.74 dB overprediction in this resonance sensitivity estimate. No fit was made to this pair.
Inputs: Compare Wall B = yes; Leaf 1 effective density = 784.6 kg/m³; Leaf 1 total material thickness = 13 mm; Leaf 2 effective density = 784.6 kg/m³; Leaf 2 total material thickness = 13 mm; Added thickness on leaf 1 = 13 mm; Added board density = 784.6 kg/m³; Total equivalent open area = 0 cm²; the others as above.
| Result | Source | This calc |
|---|---|---|
| Wall B − A · 63 Hz band (sensitivity) | 2.8 ± 6 dB | 8.542 dB |
| Wall B − A · 125 Hz band | 4.3 ± 3 dB | 6.017 dB |
| Wall B − A · 500 Hz band | 4.8 ± 3 dB | 6.021 dB |
Review example: exact 160 Hz band near resonance
Source: Independent reviewer computation for two 11 kg/m² leaves and the 20 mm cavity. The nominal 160 Hz label has an exact 158.489319 Hz centre under IEC 61260-1:2014 §§5.2–5.6. The 8.05 dB value is the model comparison supplied by the reviewer. https://preview.sist.si/sist-preview/13383/3c4ae3e762b540cc8111744cb8f0ae8e/IEC-61260-1-2014.pdf
Inputs: Leaf 1 effective density = 880 kg/m³; Leaf 2 effective density = 880 kg/m³; Face-to-face cavity depth = 20 mm; Air-spring loss factor = 0.03; Total equivalent open area = 0 cm²; Use finer frequency sampling = yes; Integration samples per third octave = 384; the others as above.
| Result | Source | This calc |
|---|---|---|
| Band centres used for integration [6] | 158.5 Hz | 158.5 Hz |
| Sealed third-octave band TL [6] | 8.05 ± 0.015 dB | 8.05 dB |