Rechner zur Wandschalldämmung: Massegesetz, zweischalige Wände & Leckagen

Schätzen Sie das Schalldämm-Maß von Wänden, die Masse-Luft-Masse-Resonanz, Koinzidenzeinbrüche und den Einfluss von Öffnungen ab. Vergleichen Sie einschalige und getrennte zweischalige Wände anhand geschätzter STC-/Rw-Werte.

#acoustic leakage #air leaks #double walls #mass law #mass–air–mass resonance #Rw #soundproofing #STC

Use this wall sound insulation calculator to estimate how much airborne sound a partition stops at different frequencies. It is intended for studio builders, engineers and students comparing wall assemblies. The plots show the effect of air-spring resonance, coincidence and open bypasses. Use the STC and Rw estimates as screening summaries of the spectrum.

Choose a single leaf or a separated double leaf. Set each leaf’s effective density and total solid material thickness. Their product is its surface mass. For example, a 12.5 mm board with a surface mass of 10 kg/m² has an effective density of 800 kg/m³. Multiple boards fixed to one frame form one leaf. Use the effective critical frequency of that leaf, especially if it contains bonded layers.

For a double wall, enter the distance between the inner leaf faces. The cavity depth includes the two frame depths, any space between them and any insulation in those spaces. The model assumes independent frames and a fibrous absorber. Under Details, enable room air temperature and pressure to use your local conditions. Finer frequency sampling gives a closer look at narrow resonance dips.

Enter the gross partition area and any equivalent open area. A uniform gap has an area equal to its width times its length. The model treats that opening as an unobstructed path through the whole assembly. Compare the sealed and open-wall curves to see when the bypass controls the result. The wall STC calculator rates the estimated 125–4000 Hz bands. The Rw estimator uses 100–3150 Hz. Inspect the low-frequency curve for bass, drums or machinery.

Open Details for three optional comparisons. Largest opening for a target gives an equivalent area, a uniform width and a signed area margin at the inspection frequency. If a door or window is included, the allowance uses the insert’s area, tested TL and selected frequency basis. A negative margin means the opening exceeds the target allowance. Wall B adds a 12.5 mm board and 10 kg/m² to leaf 1 by default. Check the remaining depth and compare the TL in the 63, 125 and 500 Hz bands. Wall B inherits Wall A’s critical frequencies unless you override them. Treat the 63 Hz gain as a sensitivity estimate near resonance.

For Door or window, enter the tested TL of the installed assembly, including its frame and seals. The default comparison uses the third-octave band nearest to the inspection frequency. Select single-frequency mode when you have a tested narrowband TL at that frequency. The wall, insert and any separate opening are combined by transmitted power. The power shares show which path carries most sound.

The fixed NRC benchmark shows how the model compares with laboratory data. Field performance also depends on supports, workmanship and surrounding rooms. Shared studs, ducts, flanking paths, empty cavities, triple leaves and thick masonry require other models or measured data. This calculator provides estimates for design comparisons. Use tested ratings for specifications and check against the standard in force. Installation work belongs to a qualified person.

So wird gerechnet

Surface mass is m=ρleaftm=rho_{leaf}t. The published default uses reference air density of 1.2 kg/m³ and sound speed of 343 m/s. Enable room air temperature and pressure under Details to calculate both dry-air properties with CoolProp. The acoustic impedance is Z0=ρcZ_0=rho c and the adiabatic bulk modulus is B=ρc2B=rho c^2.

Single leaf

Use the high-mass approximation to the field-incidence mass law, RM=20log⁡10(πfm/Z0)−5R_M=20log_{10}(pi f m/Z_0)-5. It follows by keeping the dominant mass term in Ashmore et al. (2015), p. 3, Eq. 4, and corresponds to the rounded SI form in Ballagh (2004), Eq. 1. Use the dimensionless ratio x=πfm/Z0x=pi f m/Z_0 to identify the low-mass limit. The tool warns when x<3x<3 at the low end of the modeled mass-law range. The cutoff flags use of the asymptote in a region where a finite-angle limp-leaf model can differ appreciably. At and above the critical frequency use Ashmore et al., Eq. 6, Rc=20log⁡10(πfm/Z0)+10log⁡10(2ηf/(πfc))R_c=20log_{10}(pi fm/Z_0)+10log_{10}(2eta f/(pi f_c)). Interpolate in log frequency from fc/2f_c/2 to fcf_c.

Separated double leaf

The resonance is f0=(B/d)(1/m1+1/m2)/(2π)f_0=sqrt{(B/d)(1/m_1+1/m_2)}/(2pi). In the middle and upper regimes, Sharp's absorbent-cavity correction to the sum of the leaf TLs is min⁡(6,6+20log⁡10(f/fL))min(6,6+20log_{10}(f/f_L)), with fL=(56.23 m/s)/df_L=(56.23,mathrm{m/s})/d. This is the intersection of the two published asymptotes reproduced in Ballagh (2004), Eqs. 5–6. The commonly quoted 55/d55/d is a rounded transition.

Below f0f_0 use a loaded normal-incidence network with series normalized leaf impedances zj=iωmj/Z0z_j=iomega m_j/Z_0 and shunt cavity admittance y=iωdZ0/[B(1+iηa)]y=iomega d Z_0/[B(1+ieta_a)]. Form its transfer matrix, whose entries are A=1+z1yA=1+z_1y, Bm=z1+z2+z1yz2B_m=z_1+z_2+z_1yz_2, C=yC=y and D=1+yz2D=1+yz_2. With unit incident pressure, tp=2/(A+Bm+C+D)t_p=2/(A+B_m+C+D) and rp=(A+Bm−C−D)/(A+Bm+C+D)r_p=(A+B_m-C-D)/(A+B_m+C+D). The reflected, transmitted and dissipated fractions are ∣rp∣2|r_p|^2, ∣tp∣2|t_p|^2 and Re⁡(y)∣(1+z2)tp∣2operatorname{Re}(y)|(1+z_2)t_p|^2. The checks sum these raw fractions, including a lossless case. Field estimates subtract 5 dB from the network TL and clip TL at zero. From f0f_0 to 2f02f_0, blend transmitted power into Sharp's asymptote using a cubic smoothstep in log frequency. The network and this blend extend Sharp's asymptotes through the resonance.

Openings, bands and ratings

Use τ=10−R/10tau=10^{-R/10}. Add area-weighted transmitted power for the wall, an optional tested insert and the unobstructed bypass (τ=1tau=1), following ASHRAE Fundamentals, Ch. 8, Eq. 41. For an insert area fraction aia_i, first compute closed-partition transmission τclosed=(1−ai)τw+aiτitau_{closed}=(1-a_i)tau_w+a_itau_i. An opening replaces opaque wall area, so its limiting fraction is (τtarget−τclosed)/(1−τw)(tau_{target}-tau_{closed})/(1-tau_w), bounded by the available area fraction 1−ai1-a_i. A target above the closed-partition TL is infeasible. With an insert, use the same third-octave or single-frequency basis for both the opening allowance and the composite TL.

Third-octave TL averages transmitted power at nine log-frequency midpoints per band before conversion to dB. The default spectrum uses 181 log-spaced points from 50 to 5000 Hz. Finer frequency sampling uses IEC 61260-1:2014 exact base-10 centres and edges. The centre frequencies are 1000⋅10k/101000cdot10^{k/10} Hz with integer kk, and the edge factors relative to the centre are 10±1/2010^{pm1/20}. The plots and tables keep nominal band labels. Finer mode adds plot points around each active air-spring resonance and uses 96 band midpoints at its default setting or 192 for the fixed NRC benchmark. Compare Wall A and Wall B using integrated band TL and the same opening. In insert band mode, use the opaque wall TL in the band nearest to the inspection frequency. In single-frequency mode, use a tested insert TL at the inspection frequency itself. Compute each path’s share by dividing its area-weighted transmission by the total.

STC uses 125–4000 Hz and Rw uses 100–3150 Hz. Before fitting, round STC input bands to the nearest whole dB (ASTM E413-22 §5.2) and round Rw input bands to 0.1 dB (ISO 717-1:2020 §4.4). Fit the highest integer contour with total deficit up to 32 dB. STC also limits any one band's deficit to 8 dB. Read both contours at 500 Hz.

Annahmen

  • The fixed NRC benchmark uses the reference air properties by default. With the room air option enabled, the benchmark uses dry air at 20 °C and 101.325 kPa independently of the entered conditions.
  • Each leaf is broad and thin. Enter an effective coincidence frequency for the complete leaf. Surface mass alone does not establish bending stiffness.
  • The double-leaf model assumes independent supports and fibrous cavity absorption. The air-spring loss factor is a sensitivity input. No absorber product, airflow resistivity or mounting-specific damping is inferred.
  • The area-weighted transmission model assumes uniform incident sound power per area and separate wall, insert and equivalent open paths. Enter only openings outside leakage already included in the insert test.

Anwendungsbereich

Use the model for preliminary design in the plotted 50–5000 Hz range. The end third-octave bands extend beyond those limits. Enable finer frequency sampling to better resolve a narrow resonance dip on the spectrum and in the band averages. For very light leaves at low frequencies, the mass-law asymptote can clip the predicted TL to zero. For example, at 200 Hz a 1 kg/m² limp leaf gives about 2.9 dB when the angle-dependent transmission is averaged to 85°, compared with 0 dB from the clipped approximation. Use measured TL when the low-mass warning appears. Obtain tested assembly ratings for specifications and check against the standard in force.

The 63 Hz Wall B gain is a sensitivity estimate. NRC IR-761 measured +2.8 dB in the matched TL-93-270 / TL-93-271 pair (printed pp. 319 and 339) after adding one 10.2 kg/m² board. This model gives +8.54 dB at default sampling and air settings under the same mass and depth inputs. The air-spring damping and critical frequencies for that prediction are screening assumptions. No coefficients were fitted to the pair. The 6 dB tolerance in that check acknowledges the 5.74 dB overprediction. At 125 and 500 Hz the corresponding measured gains were +4.3 and +4.8 dB.

At default settings, the fixed NRC TL-93-279 model is 13.9 dB below the measurement at 63 Hz (4.3 versus 18.2 dB) and 9.3 dB above it at 2500 Hz (69.1 versus 59.8 dB). The modeled STC is 52 and the measured STC is 53. The spot-check tolerances for TL-93-279 and TL-93-262 apply only to the 125 and 500 Hz bands and the STC ratings tested. See NRC IR-761, printed pp. 316 and 330. The 30 dB insert default is a placeholder for tested data.

The model excludes room-to-room level difference, flanking transmission, shared supports, resilient mounts, empty cavities, slit diffraction, ducts, triple leaves and heavy masonry shear waves. The opening bar shows the equivalent fraction of total wall area. Thin single leaves have a minimum display width in the section. Installation work belongs to a qualified person.

Quellen

  • B. H. Sharp (1978), Prediction Methods for the Sound Transmission of Building Elements, Noise Control Engineering 11(2), 53–63. https://doi.org/10.3397/1.2832099
  • K. O. Ballagh (2004), Accuracy of Prediction Methods for Sound Transmission Loss, Inter-Noise 2004, pp.2–3. https://static1.squarespace.com/static/62b943270a6d6d4fa1970dee/t/66862bbb9374252e7a84f6d9/1720069056129/10_accuracy_of_prediction_methods_for_sound_transmission_loss.pdf
  • AAS Acoustics 2015 paper p74, Sound insulation of vacuum insulated glazing, PDF p.3, Sharp single-leaf equations. https://acoustics.asn.au/conference_proceedings/AAS2015/papers/p74.pdf
  • R. E. Halliwell et al. (1998), Gypsum Board Walls: Transmission Loss Data, NRC IRC-IR-761, printed pp.17, 316 and 330. https://doi.org/10.4224/20331556
  • ASHRAE Handbook—Fundamentals (2025), Chapter 8, Eq.41 and the 40 dB wall/1% opening example. https://handbook.ashrae.org/Handbooks/F25/IP/F25_Ch08/F25_Ch08_ip.aspx
  • ASTM E413-22, Classification for Rating Sound Insulation, §5.2 band rounding and contour-fitting procedure. https://store.astm.org/e0413-22.html
  • ISO 717-1:2020, Acoustics—Rating of sound insulation, Part 1, §4.4 band rounding before comparison (printed p.4). https://cdn.standards.iteh.ai/samples/77435/7e658360f54d4ddc9e6f23c0a1e7d41e/ISO-717-1-2020.pdf
  • I. H. Bell et al. (2014), CoolProp thermophysical property library. https://doi.org/10.1021/ie4033999
  • IEC 61260-1:2014, Electroacoustics—Octave-band and fractional-octave-band filters, Part 1, §§5.2–5.6. https://preview.sist.si/sist-preview/13383/3c4ae3e762b540cc8111744cb8f0ae8e/IEC-61260-1-2014.pdf
  • A. London (1949), Transmission of Reverberant Sound Through Single Walls, NBS RP 1998. https://doi.org/10.6028/jres.042.053

Eingaben

EingabeSymbolEinheitVorgabe
Wandmodell
“Separated double leaf, absorbent cavity” assumes separate frames.
constructionSeparated double leaf, absorbent cavity
Schale 1: effektive Dichte
If surface mass is known, divide it by total leaf thickness.
rho_1kg/m^3800
Schale 1: gesamte Materialdicket_1mm12.5
Schale 1: Koinzidenzgrenzfrequenz
Enter the measured or effective coincidence frequency of this leaf.
f_c1Hz3000
Schale 2: effektive Dichte
If surface mass is known, divide it by total leaf thickness.
rho_2kg/m^3800
Schale 2: gesamte Materialdicket_2mm12.5
Schale 2: Koinzidenzgrenzfrequenz
Enter the measured or effective coincidence frequency of this leaf.
f_c2Hz3000
Verlustfaktor der Schalen
Effective structural damping of the leaf material.
eta_leaf0.03
Lichte Hohlraumtiefe
Measure between the inner leaf faces, including insulation.
d_gapmm205
Verlustfaktor der Luftfeder
Assumed damping near the air-spring resonance.
eta_cavity0.15
Gesamte Trennwandfläche
Use gross area, including the door or window and any openings.
A_wallm^210
Gesamte äquivalente Öffnungsfläche
For an unobstructed gap, enter its length × width.
A_leakcm^210
Inspect frequency
Sets where you inspect TL and evaluate the optional opening limit.
f_probeHz500
Calculate opening limitcheck_opening_targetfalse
Target transmission loss
Uses the inspection frequency or the selected door or window basis.
R_targetdB40
Uniform gap lengthL_gapm1
Compare Wall Bcompare_wall_bfalse
Added thickness on leaf 1t_boardmm12.5
Added board density
Divide the board’s mass per unit area by its thickness to obtain its effective density.
rho_boardkg/m^3800
Maximum wall depthD_budgetmm250
Set Wall B critical frequencies
Wall B uses Wall A’s critical frequencies until you enable this.
edit_b_criticalfalse
Wall B leaf 1 critical frequencyfc_B1Hz3000
Wall B leaf 2 critical frequencyfc_B2Hz3000
Include a door or windowinclude_insertfalse
Door or window area
Use the area of the tested assembly, including its frame.
A_insertm^22
Test data frequency basisinsert_modeThird-octave band
Tested door or window TL
Enter the tested TL for the frequency basis shown in the results.
R_insertdB30
Use room air temperature and pressureuse_air_statefalse
Room air temperatureT_air°C20
Absolute air pressurep_airkPa101.325
Use finer frequency sampling
Refines the plots around resonance and uses more samples in each third-octave band.
fine_band_resolutionfalse
Integration samples per third octaven_band96

Ergebnisse

Mit den obigen Vorgabewerten liefert der Rechner:

ErgebnisWert
STC-Schätzung · mit Öffnung40
Rw-Schätzung · mit Öffnung40 dB
TL at inspect frequency · with opening39,9 dB
Loss caused by opening at inspect frequency19,3 dB
STC-Schätzung · abgedichtete Wand52
Rw-Schätzung · abgedichtete Wand53 dB
Resonanz59.1 Hz Masse-Luft-Masse-Resonanz
Öffnungsbedingte Obergrenze40 dB öffnungsbedingte Obergrenze
Maximum equivalent opening9,88 cm²
Maximum uniform gap width0,988 mm
Opening area remaining-0,12 cm²
Wall B total depth242,5 mm
Wall B depth remaining7,5 mm
Wall B mass–air–mass resonance51,2 Hz
Door or window comparison band or frequency500 Hz third-octave band
Partition TL with door or window35,2 dB
Transmitted power through opaque wall0,3 %
Transmitted power through door or window66,4 %
Transmitted power through opening33,2 %

Außerdem zeigt er: Wall B − A · 63 Hz band (sensitivity), dB; Wall B − A · 125 Hz band, dB; Wall B − A · 500 Hz band, dB.

Mit Quellen abgeglichen

Jeder Fall unten wurde mit diesem Rechner berechnet und stimmt mit dem Wert aus seiner Quelle überein (innerhalb der Toleranz, wo eine angegeben ist).

NRC TL-93-279: getrennte, abgedichtete 13-mm-Gipskartonschalen

Quelle: NRC IR-761 (1998), TL-93-279, printed p.316 / PDF p.319. Two 10 kg/m² leaves; 90+25+90 mm cavity; one 90 mm glass-fibre batt. 3000 Hz and damping are independent screening assumptions. Model checked within 3 dB only at these bands and STC; the comparison chart retains the larger low-frequency/coincidence mismatch.

Eingaben: Gesamte äquivalente Öffnungsfläche = 0 cm²; die übrigen wie oben.

ErgebnisQuelleDieser Rechner
Abgedichtet: Schalldämm-Maß im Terzband bei 125 Hz29 ± 3 dB28,024 dB
Abgedichtet: Schalldämm-Maß im Terzband bei 500 Hz60 ± 3 dB59,114 dB
STC-Schätzung · abgedichtete Wand53 ± 352

NRC TL-93-262: getrennte, abgedichtete 16-mm-Gipskartonschalen

Quelle: NRC IR-761 (1998), TL-93-262, printed p.330 / PDF p.333. Surface masses 11.6 and 11.4 kg/m²; cavity 205 mm with two 65 mm glass-fibre batts. 2500 Hz is an assumed critical frequency for 16 mm gypsum, not a fitted NRC property. The wider 5 dB low-band/STC tolerance acknowledges unmodeled fill and finite-panel effects.

Eingaben: Schale 1: Koinzidenzgrenzfrequenz = 2.500 Hz; Schale 2: Koinzidenzgrenzfrequenz = 2.500 Hz; Gesamte äquivalente Öffnungsfläche = 0 cm²; Schale 1: effektive Dichte = 725 kg/m³; Schale 1: gesamte Materialdicke = 16 mm; Schale 2: effektive Dichte = 712,5 kg/m³; Schale 2: gesamte Materialdicke = 16 mm; die übrigen wie oben.

ErgebnisQuelleDieser Rechner
Abgedichtet: Schalldämm-Maß im Terzband bei 125 Hz34,4 ± 5 dB30,446 dB
Abgedichtet: Schalldämm-Maß im Terzband bei 500 Hz61,2 ± 3 dB61,541 dB
STC-Schätzung · abgedichtete Wand58 ± 554

Bewertungsalgorithmus: gemessenes Spektrum NRC TL-93-279

Quelle: NRC IR-761, TL-93-279 published STC 53. This verifies contour fitting from the independent measured spectrum, not prediction accuracy.

Eingaben: die obigen Vorgabewerte.

ErgebnisQuelleDieser Rechner
STC aus Messdaten von NRC TL-93-2795353

Bewertungsalgorithmus: gemessenes Spektrum NRC TL-93-262

Quelle: NRC IR-761, TL-93-262 published STC 58. This verifies contour fitting from the independent measured spectrum.

Eingaben: die obigen Vorgabewerte.

ErgebnisQuelleDieser Rechner
STC aus Messdaten von NRC TL-93-2625858

ASHRAE: 40-dB-Wand mit 1% Öffnungsfläche

Quelle: ASHRAE Handbook—Fundamentals (2025), Ch.8 Eq.41 worked example: 40 dB partition with 1% open area gives 20 dB overall. The exact energy sum is 19.957 dB; tolerance covers the published rounding. https://handbook.ashrae.org/Handbooks/F25/IP/F25_Ch08/F25_Ch08_ip.aspx

Eingaben: die obigen Vorgabewerte.

ErgebnisQuelleDieser Rechner
Publizierter Leckage-Referenzfall: 40-dB-Wand, 1% offen20 ± 0,05 dB19,957 dB

Review-Regressionstest: 7 cm² Öffnung ergibt STC 42

Quelle: Independent reviewer boundary example supplied with this review: default wall with A_leak = 7 cm² must give STC 42 after integer band rounding. Rounding rule: ASTM E413-22 §5.2, https://store.astm.org/e0413-22.html. This is a contour-rounding regression, not a published laboratory wall result.

Eingaben: Gesamte äquivalente Öffnungsfläche = 7 cm²; die übrigen wie oben.

ErgebnisQuelleDieser Rechner
STC-Schätzung · mit Öffnung4242

Review-Regressionstest: 7.2 cm² Öffnung ergibt Rw 41 dB

Quelle: Independent reviewer boundary example supplied with this review: default wall with A_leak = 7.2 cm² must give Rw 41 dB after rounding bands to 0.1 dB. Rule: ISO 717-1:2020 §4.4, printed p.4 / attached preview p.10. This is a contour-rounding regression, not a laboratory measurement.

Eingaben: Gesamte äquivalente Öffnungsfläche = 7,2 cm²; die übrigen wie oben.

ErgebnisQuelleDieser Rechner
Rw-Schätzung · mit Öffnung41 dB41 dB

NRC TL-93-270 to TL-93-271 added-board gain

Quelle: NRC IR-761, TL-93-270 and TL-93-271, printed pp.319 and 339 (PDF pp.322 and 342). One 10.2 kg/m² board was added to a 205 mm cavity assembly with two 10.2 kg/m² leaves. Measured TL changes at 63, 125 and 500 Hz were +2.8, +4.3 and +4.8 dB. The 63 Hz tolerance explicitly covers the documented 5.74 dB overprediction in this resonance sensitivity estimate. No fit was made to this pair.

Eingaben: Compare Wall B = ja; Schale 1: effektive Dichte = 784,6 kg/m³; Schale 1: gesamte Materialdicke = 13 mm; Schale 2: effektive Dichte = 784,6 kg/m³; Schale 2: gesamte Materialdicke = 13 mm; Added thickness on leaf 1 = 13 mm; Added board density = 784,6 kg/m³; Gesamte äquivalente Öffnungsfläche = 0 cm²; die übrigen wie oben.

ErgebnisQuelleDieser Rechner
Wall B − A · 63 Hz band (sensitivity)2,8 ± 6 dB8,542 dB
Wall B − A · 125 Hz band4,3 ± 3 dB6,017 dB
Wall B − A · 500 Hz band4,8 ± 3 dB6,021 dB

Review example: exact 160 Hz band near resonance

Quelle: Independent reviewer computation for two 11 kg/m² leaves and the 20 mm cavity. The nominal 160 Hz label has an exact 158.489319 Hz centre under IEC 61260-1:2014 §§5.2–5.6. The 8.05 dB value is the model comparison supplied by the reviewer. https://preview.sist.si/sist-preview/13383/3c4ae3e762b540cc8111744cb8f0ae8e/IEC-61260-1-2014.pdf

Eingaben: Schale 1: effektive Dichte = 880 kg/m³; Schale 2: effektive Dichte = 880 kg/m³; Lichte Hohlraumtiefe = 20 mm; Verlustfaktor der Luftfeder = 0,03; Gesamte äquivalente Öffnungsfläche = 0 cm²; Use finer frequency sampling = ja; Integration samples per third octave = 384; die übrigen wie oben.

ErgebnisQuelleDieser Rechner
Band centres used for integration [6]158,5 Hz158,5 Hz
Sealed third-octave band TL [6]8,05 ± 0,015 dB8,05 dB