Motor Rewinding Calculator: Turns per Coil and Wire Size
Size a three-phase stator rewind from its dimensions or preserve an old winding’s flux at a new voltage or frequency. Check turns, wire size, slot fill, tooth and yoke densities.
This motor rewinding calculator helps repair shops, technicians and students estimate a three-phase induction motor winding from a measured stator, or adapt a known winding to another voltage or frequency. It combines a turns per coil calculator with a motor winding wire size calculator and checks the magnetic loading of the teeth and back iron.
Choose Target air-gap flux density when the old winding is unavailable. Measure the bore, active stack length, lamination outside diameter and slot profile. Enter the slot count, poles, winding layers, coil span and parallel circuits. The target is the peak sinusoidal air-gap density, which is larger than its pole-average value. Set the intended rated line current separately: dimensions alone cannot establish the motor’s output rating.
Choose Keep the recorded old flux for a voltage or frequency conversion. Enter the old turns per coil, coil span, connection and parallel circuits. Add the old wire diameter and wires in hand to check its current density and slot fill. In target-flux mode, the optional old-record switch enables the same comparison. Use measured bare-copper diameters rather than assuming an AWG or SWG number.
The calculator obtains the winding factor from the actual slot EMFs. It rounds coil turns upward, then recomputes the resulting flux densities. A large rounding change can matter in a low-turn winding; increasing parallel circuits can provide finer turn resolution when an equal circuit arrangement exists. The winding schedule identifies phase, coil return slot and start-side polarity. Coils assigned to a circuit must be connected with the indicated polarity; the schedule is not a terminal-board wiring diagram.
The suggested wire uses equal strands and rounds bare diameter upward on the selected stock increment. Compare copper needed for the current with copper allowed by the slot-fill target. Enamel, liners, phase paper, wedges and practical insertion clearances still need a physical fit check. A current-density target is a design input, not a prediction of winding temperature.
To rewind a 50 Hz motor for 60 Hz, compare phase volts per hertz and effective series turns. Star–delta connections change phase voltage and line current. The equivalent-ratings table shows both connections at 50 and 60 Hz for the new winding at its calculated flux and entered phase current. These are electrical equivalents, not approved mechanical or thermal ratings.
Press play to see the winding MMF rotate. The section uses the entered slot geometry and colours iron by the calculated fundamental flux-density distribution. This tool covers balanced integral-slot, uniform-pitch lap windings. It does not determine starting torque, efficiency, temperature rise, rotor suitability, permissible shaft speed or hazardous-area certification. Complete a rewind with core, insulation, resistance, polarity, no-load and load testing; installation work belongs to a qualified person.
How it is calculated
The sinusoidal fundamental gives pole flux , with the total poles and active length excluding ducts. The slot-EMF star supplies for the actual winding; for an integral-slot lap winding it equals . Phase EMF is . This is the rewind relation given in EASA/AEMT (2003), printed p. 2-18.
There are coils per phase for coil sides per slot. Each of equal circuits has series coils. Unrounded turns per coil are . The tool rounds upward to the next whole turn and uses the actual turns to recompute flux. In preserve mode it first solves the old winding for flux; phase voltage, frequency, winding factor, layers and circuits all enter the conversion.
For the tooth check, integrate sinusoidal bore flux over one slot pitch: , where . Divide by the narrowest tooth section times the stacking factor. At radius and slot chord width , tooth width is . Check the mouth and both body ends. Each yoke branch carries half the pole flux, so .
Copper per turn must be at least and at most . The suggested equal-strand diameter meets the first bound; the second is checked independently after diameter rounding. Gross slot body area is the trapezoid below the mouth. Wires in hand divide conductor current; parallel circuits divide phase current.
Balanced sinusoidal phase currents and the exact slot current sheet give the stepped stator MMF. The library evaluates its spatial harmonics analytically, including forward/backward rotating components. Fundamental iron colours use the sinusoidal flux model, with peak-section density uniform along each tooth and uniform across yoke thickness. These field and section equations are derived here from Faraday’s law and magnetic-flux continuity.
Assumptions
Three phases; balanced integral-slot windings, with slots a multiple of three times the total poles. Two-layer windings have one uniform span no greater than pole pitch. Single-layer windings use full-pitch positive-to-negative phase-belt pairing. Concentric, mixed-turn, fractional-slot and unequal-path windings need a separate layout calculation.
All coils have equal whole turns. Equal-emf circuits contain complete equivalent coil groups; the allowed circuit count divides the poles for two layers or half the poles for one layer. Phase A/B/C current angles are 0°/120°/240°. No skew correction is applied.
The fundamental bore field is sinusoidal; tooth leakage, fringing and saturation redistribution are omitted. Active stack length and stacking factor apply to both iron sections. The same induced/terminal voltage ratio is used for the old and new states. Bare wire is round copper, with identical strands. Density and fill limits are user-selected screening targets, not material or thermal ratings.
Where it applies
This is a winding and magnetic-loading design calculation. An unknown stator does not establish a unique winding, rated power or current: the target flux, current density and cooling duty must be chosen from sound design information. Confirm tooth and yoke targets against the actual lamination grade. “Selected limits met” covers only the entered density, bare-copper fill and individual-strand width checks.
The flux picture is a fundamental magnetic-circuit distribution, not FEM. It does not resolve slot-tip hot spots or local saturation. The stator-current MMF is not the net loaded air-gap MMF, because rotor currents are not modelled; their phase relation is illustrative. The wire inset shows at most about 180 strand sections with an illustrative placement, not an insertion or packing solution. Its enamel estimate does not replace supplier maximum overall diameter or a physical slot-fit trial.
At 50–60 Hz conversion, constant flux does not guarantee unchanged losses, temperature, torque, fan performance or permissible shaft speed. Harmonic bars show odd electrical space orders through 25, analytically evaluated; the sizing uses only the fundamental. Exclude single-phase, multi-speed, hazardous-area/explosion-proof and unusual winding designs. Retain or reduce mean length of turn where possible, and verify resistance and losses after repair. No time integration or spatial field solver is used, so there is no numerical mesh truncation in the sizing results. The analytic yoke field is sampled on a 101 × 101 picture grid and smoothly interpolated for display.
The 10 kW published reference checks turns, copper current density and pole flux; its nonlinear tooth/yoke maxima are outside this uniform-section model. The Illinois reference contains a 3-versus-4-turn inconsistency, documented in that check.
Retain two layers when the recorded winding has two layers. EASA/AEMT (2003), §4.3, printed p. 2-18 (PDF p. 47), advises against replacing a two-layer winding with one layer because this reduces efficiency. Preserving fundamental flux and meeting the numerical density/fill limits do not address that efficiency penalty.
References
- EASA/AEMT (2003), The Effect of Repair/Rewinding on Motor Efficiency and Good Practice Guide, p. 2-18 and Appendices 1–3. https://ges-group.com/wp-content/uploads/2019/11/EASA-Rewind-Study.pdf
- EASA (2017), Information needed to complete a data verification & redesign request. https://easa.com/resources/resource-library/information-needed-to-complete-a-data-verification-redesign-request
- Caruso, Di Tommaso, Miceli and Rizzo (2018), Computer-aided analysis and design procedure for rotating induction machine magnetic circuits and windings, Tables 2, 4, 5. https://doi.org/10.1049/iet-epa.2017.0310
- T. A. Keim (2016), Induction motor seminar, University of Illinois, p. 8. https://energy.ece.illinois.edu/files/2016/10/9-16-16-induction-motor-seminar-handout.pdf
- Background reading: Boldea and Nasar, The Induction Machine Handbook, 1st ed., CRC Press (2002), winding MMF and design chapters. https://doi.org/10.1201/9781420042658
- Background reading: M. G. Say, The Performance and Design of Alternating Current Machines, 3rd ed. (1983 reprint), ISBN 9788123910277. https://www.cbspd.com/product/the-performance-and-design-of-alternating-current-machines
Inputs
| Input | Symbol | Unit | Default |
|---|---|---|---|
| Rewind basis | design_mode | Target air-gap flux density | |
| New line voltage | V_line | V | 400 |
| New frequency | f_new | Hz | 50 |
| New connection | conn_new | Star (Y) | |
| New rated line current Use the intended nameplate current; the stator dimensions alone do not determine power. | I_line | A | 14 |
| Target peak air-gap flux density Peak of the sinusoidal fundamental; pole-average density is 2/π times this value. | B_target | T | 0.8 |
| Induced / terminal phase voltage Allows for stator impedance drop; use 1 for a no-load first estimate. | k_emf | 0.97 | |
| Stator bore | D_bore | mm | 150 |
| Active stack length Exclude axial ventilation ducts. | L_stack | mm | 144 |
| Lamination outside diameter | D_outer | mm | 250 |
| Stator slots | Q_slots | 36 | |
| Poles | P_poles | 4 | |
| Layers | layer_type | Two layers, uniform-pitch lap | |
| Coil span in slots A coil in slots 1 and 9 has span 8. | y_span | 8 | |
| Parallel circuits per phase Equal whole coil groups in each circuit; wires in hand are a separate input. | a_paths | 1 | |
| Slot mouth width | b_open | mm | 2.5 |
| Slot mouth depth | h_open | mm | 1.5 |
| Slot body width at mouth end | b_top | mm | 6 |
| Slot body width at back | b_bottom | mm | 10 |
| Total radial slot depth | h_slot | mm | 25 |
| Iron stacking factor | k_stack | 0.95 | |
| Tooth density screening limit Set from the lamination grade and the original design. | B_tooth_limit | T | 1.8 |
| Yoke density screening limit | B_yoke_limit | T | 1.5 |
| Maximum bare-copper slot fill Bare copper area / gross slot body area; allow for liners, separators, enamel and insertion. | k_fill | 0.42 | |
| Design current density Choose from the original thermal design, cooling, duty and insulation class. | J_limit | A/mm^2 | 5 |
| Equal wires in hand | n_hand | 2 | |
| Available bare-diameter increment The suggestion rounds upward on this increment; confirm stocked magnet-wire diameters. | d_step | mm | 0.05 |
| Radial enamel build Use the wire supplier's maximum finished diameter to confirm fit. | enamel | mm | 0.035 |
| Compare a recorded old winding | check_old | false | |
| Old line voltage | V_old | V | 400 |
| Old frequency | f_old | Hz | 50 |
| Old connection | conn_old | Star (Y) | |
| Old rated line current | I_old_line | A | 14 |
| Old layers | old_type | Two layers, uniform-pitch lap | |
| Old coil span in slots | y_old | 8 | |
| Old parallel circuits per phase | a_old | 1 | |
| Old turns per coil | T_old | 11 | |
| Old equal wires in hand | n_old | 2 | |
| Old bare wire diameter | d_old | mm | 1.35 |
| Electrical field angle | wt | deg | 25 |
Results
With the default inputs above, the calc gives:
| Result | Value |
|---|---|
| Turns per coil | 11 |
| Series turns per circuit | 132 |
| Bare diameter per strand | 1.35 mm |
| Current density | 4.89 A/mm² |
| Bare copper slot fill | 0.335 |
| Peak air-gap density | 0.749 T |
| Peak tooth density | 1.397 T |
| Peak yoke density | 1.182 T |
| Fundamental winding factor | 0.9452 |
| Copper per turn required | 2.8 mm² |
| Copper per turn allowed by fill | 3.589 mm² |
| Governing design check | Selected limits met |
Checked against sources
Each case below was calculated by this calc and agrees with the value from its source (within the tolerance where one is shown).
Illinois 36-slot, two-parallel-Y example
Source: Illinois induction motor seminar, T. A. Keim, 16 Sep 2016, p. 8: https://energy.ece.illinois.edu/files/2016/10/9-16-16-induction-motor-seminar-handout.pdf . The heading says 3-turn coils but the arithmetic uses 4 and gives 19.95 effective series turns. This check explicitly uses 4 turns; the heading would instead give about 14.96. No formula is adjusted to follow the inconsistent heading.
Inputs: Old coil span in slots = 6; Old turns per coil = 4; Old parallel circuits per phase = 2; Compare a recorded old winding = yes; the others as above.
| Result | Source | This calc |
|---|---|---|
| Old effective series turns | 19.95 | 19.949 |
EASA published 72-slot lap rewind
Source: EASA/AEMT, The Effect of Repair/Rewinding on Motor Efficiency (2003), Appendix 3 Example 2, printed p. 3-8 (PDF p. 63): https://ges-group.com/wp-content/uploads/2019/11/EASA-Rewind-Study.pdf . Published 72 slots, 4 poles, lap span 15, 15 turns/coil; pitch and distribution factors 0.966 and 0.956; 83.13 effective turns per six-coil group. Four groups give 332.52, subject to the publication's rounding. The dimensions here are test geometry, not the example's unspecified dimensions.
Inputs: Stator slots = 72; Stator bore = 300 mm; Lamination outside diameter = 500 mm; Coil span in slots = 15; Old coil span in slots = 15; Old turns per coil = 15; Rewind basis = Keep the recorded old flux; Compare a recorded old winding = yes; the others as above.
| Result | Source | This calc |
|---|---|---|
| Turns per coil | 15 | 15 |
| Pitch factor | 0.966 | 0.9659 |
| Distribution factor | 0.956 | 0.9561 |
| Old effective series turns | 332.5 | 332.5 |
Published 10 kW IM1 winding and wire
Source: Caruso et al. (2018), IET Electric Power Applications 12(6), Tables 2, 4 and 5, IM1. DOI: https://doi.org/10.1049/iet-epa.2017.0310 . Published 220 V delta, 50 Hz, 37.71 A line, 120 series turns/phase, 10 turns/coil, three 1.25 mm wires, 5.91 A/mm²; 208.9 V induced phase EMF and 8.292 mWb pole flux. The voltage-drop factor is set from the reported EMF. The tiny flux discrepancy is consistent with rounded table values and winding factor. Tooth/yoke peaks from their nonlinear magnetic-circuit and FEM model are not asserted as exact results of this uniform-section screening model.
Inputs: Old line voltage = 220 V; Old connection = Delta (Δ); Old rated line current = 37.71 A; Induced / terminal phase voltage = 0.9495; Old turns per coil = 10; Old equal wires in hand = 3; Old bare wire diameter = 1.25 mm; Compare a recorded old winding = yes; the others as above.
| Result | Source | This calc |
|---|---|---|
| Old series turns per circuit | 120 | 120 |
| Old turns of conductor per slot | 20 | 20 |
| Old current density | 5.91 A/mm² | 5.914 A/mm² |
| Old flux per pole | 0.008292 ± 1 × 10⁻⁵ Wb | 0.008296 Wb |