Size a ZVS induction heater work coil and tank capacitor. Calculate loaded resonance, skin depth, RMS currents, workpiece power and heating time through the Curie transition.
A ZVS induction heater can draw a modest DC current while hundreds of amperes circulate between its work coil and tank capacitor. This induction heater calculator connects those electrical stresses to the power actually absorbed by a cylindrical metal workpiece and its predicted heating time. It is intended for engineers, students and builders comparing coil dimensions, capacitor banks and heating conditions.
Start with the supply voltage, actual capacitor bank capacitance and its ESR at operating frequency. Enter the work coil's inside diameter, winding length, turns and copper tube dimensions. Include the complete copper lead length and an estimate of its stray inductance. The workpiece should fit concentrically inside the coil, with its heated length close to the winding length. The drawing updates to those dimensions; drag the diameter handle to explore the fit.
As a work coil inductance calculator, the tool applies the Nagaoka finite-length correction rather than treating every winding as an infinitely long solenoid. It then represents the workpiece as a loosely coupled shorted secondary. Coupling depends strongly on clearance, overlap and the surrounding metal. The flux linkage adjustment lets you calibrate the estimate against a measured loaded coil. Without that calibration, absorbed power is a design estimate.
Material inputs matter as much as geometry. Supply resistivity at 20 °C, its temperature coefficient, effective relative permeability and a mean heat capacity appropriate to your temperature range. For nonmagnetic conductors, set relative permeability to one. For steel, the model brings permeability smoothly to unity at the entered Curie temperature. The induction heating skin depth calculator therefore shows why the same workpiece can respond very differently before and after it becomes nonmagnetic.
The ZVS induction heater coil calculator solves loaded parallel resonance at each temperature, including copper and capacitor losses. It reports coil and capacitor RMS currents, tank peak voltage, electrical efficiency and the capacitor bank's reactive duty. The maximum current and reactive rating over the heating sweep are the quantities to compare with component data. The optional design frequency gives an ideal starting capacitance at the initial workpiece temperature.
Press play to follow the heating transient. The coloured section shows current penetration, while the exposed metal changes its incandescent colour with computed mean temperature. The thermal integration includes convection and radiation and stops at the requested target or simulation duration. A target not reached within that duration is reported explicitly.
This model covers a solid cylindrical workpiece and a cooled single-layer coil. It does not predict hardening depth, melting, local hot spots, startup or MOSFET switching transients. Validate coupling, material properties, cooling and capacitor ratings for the actual assembly before selecting hardware.
How it is calculated
The empty coil is a single cylindrical current sheet with Nagaoka's finite-length factor (Nagaoka, 1908, Eqs. I–II, printed p. 316). Complete elliptic integrals are evaluated by 512-panel quadrature. With mean radius r and winding length ℓ, L = μ₀πr²N²K/ℓ; lead inductance is added separately.
The workpiece is a shorted, one-turn cylindrical secondary. This implements the transformer and skin-effect approach described in onsemi AN-9012, printed pp. 1–2. The external secondary inductance uses the same current-sheet expression with one turn. The adjustable coupling estimate is k = k_link(r_work/r_coil)√(ℓ_short/ℓ_long), and M = k√(L_winding L_secondary). This geometry estimate is an assumption to calibrate, not a measured coupling law.
At every temperature, ρ = ρ₂₀[1 + α(T − 20 °C)]. Effective relative permeability falls by a smooth cubic from the entered value at T_C − ΔT_C to unity at T_C, and remains unity above it. Skin depth is δ = √[2ρ/(ωμ₀μᵣ)]. The surface impedance gives R₂ = ρπd/(ℓδ) and Z₂ = (1 + j)R₂ + jωL₂. Reflected impedance is Z_ref = ω²M²/Z₂. Copper resistance uses the tube's outer conducting annulus of depth min(δ_Cu, wall), multiplied by the entered proximity factor; lead resistance is included.
A bracketed root solve finds zero imaginary part of the total parallel admittance, including capacitor ESR. For a stiff supply and sinusoidal current-fed push-pull operation, each feed choke has zero mean voltage: the half-sine drain waveform has mean V_peak/π. Thus the ideal differential tank peak is πV_dc and its RMS value is πV_dc/√2. Branch currents follow their complex impedances. Separate I²R terms give workpiece, copper and capacitor losses; capacitor reactive rating is I_cap²/(ωC), reported in kV·A, numerically kvar. Total loaded Q is the capacitor reactive duty divided by the sum of workpiece, copper and capacitor ESR losses. Its minimum over the entire temperature sweep guards the sinusoidal-voltage assumption, independently of playback time. The design capacitance cancels the coil susceptance at the requested frequency and initial temperature; that recommendation neglects capacitor ESR.
The thermal ODE integrates m c_p dT/dt = P_work(T) − hA(T − T_air) − εσA(T_K⁴ − T_air,K⁴), plus cumulative absorbed and lost energy. The temperature grid concentrates samples in the Curie transition and uses shape-preserving interpolation; an adaptive Dormand–Prince pass locates the target crossing or duration limit. A second pass evaluates dense solver output on a uniform grid over that actual run interval, supplemented by finely subdivided adaptive intervals; playback uses shape-preserving interpolation of this history. The image uses |J(x)|/|J_surface| = exp(−x/δ); the dashed circle marks one skin depth. Incandescent colour is estimated from Planck radiance at three visible wavelengths, with fixed display exposure.
Assumptions
A centered solid cylindrical workpiece, a single-layer round copper tube coil, and approximately equal heated and winding lengths. The whole workpiece is represented by one temperature. Density, mean heat capacity, thermal conductivity, convection coefficient and emissivity are user inputs. The starting steel-like values are illustrative engineering assumptions, not a certified alloy dataset.
The supply maintains its entered voltage and can furnish the displayed DC current. The coil stays at the entered copper temperature through cooling. The driver efficiency is an allowance for switches and feed chokes; it does not alter the ideal tank voltage. Proximity loss and coupling require calibration for an actual assembly. Annealed copper uses ρ₂₀ = 1.724 × 10⁻⁸ Ω·m and α = 0.00393 K⁻¹ (standard IACS values). Hysteresis loss, saturation and permeability's field dependence are omitted.
Where it applies
The workpiece surface-impedance and exponential-profile approximation needs diameter ≥ 8δ throughout the temperature sweep; a condition flags smaller parts. It does not solve the weak-skin cylindrical Bessel problem. Finite conductor pitch, discrete turns, lead layout and end fields introduce additional inductance error beyond the Nagaoka current-sheet solution. Treat the geometric coupling estimate as a starting point and replace its adjustment using measured loaded impedance.
The heating time is a mean-temperature estimate, not a surface or core temperature prediction for hardening. Biot number and radial diffusion time conditions flag conditions needing a spatial thermal model. Phase changes, latent heat, alloy-specific Curie/heat-capacity anomalies, temperature gradients, support conduction, coil-to-part radiation and oxidation changes in emissivity are outside the model. Set a suitable average heat capacity and temperature coefficient over the intended range; the linear resistivity law is not an alloy property curve.
The default temperature sweep has 240 intervals. An adaptive solve first finds the actual run duration; 1200 uniform history intervals then span that duration, even when the requested maximum duration is much longer. Subdivided adaptive intervals add samples around rapid changes so a long unreached-target tail cannot erase the earlier transient. The uniform history resolution is adjustable under Advanced; adaptive intervals receive at least four subdivisions, eight at the default setting. Both ODE passes use adaptive steps, and separate convergence checks cover stopping time, playback temperature and playback power. The end section is fitted to its own scale. The 151 × 151 current-field image samples the analytic skin profile and blends cells; cold skin layers thinner than a display cell are not spatially resolved. No thermal diffusion field is inferred from its colour. Optical colour is illustrative, not calibrated pyrometry.
The low-Q warning uses the worst capacitor-reactive-duty/total-real-loss ratio across the specified temperature sweep, including capacitor ESR. The sweep extends to the requested target even if it is not reached within the duration limit, so this guard is conservative. Low Q, supply current limiting, imperfect gate timing and feed-choke saturation invalidate the π-voltage assumption. Tank voltage, circulating current and capacitor reactive duty can be much larger than the DC supply values. Check the capacitor maker's AC voltage, RMS current, ESR, frequency and cooling ratings together; a DC voltage marking alone is insufficient. The small circuit omits the gate network, protection and parasitics. This tool does not establish startup, ZVS margin, MOSFET overshoot or a working protection design.
Reference cases verify published inductance coefficients and skin depths. Complete heater power and time predictions have not been validated against a measured assembly; coupling and material data dominate that uncertainty.
References
- H. Nagaoka, Note on the Self-inductance of Solenoids, 1908, pp. 314–325. https://doi.org/10.11429/ptmps1907.4.16_314 (open source s3; scanned numerical table on PDF p. 12).
- onsemi / Fairchild, AN-9012, Induction Heating System Topology Review, rev. 1.0.4 (2013), printed pp. 1–4. https://www.onsemi.com/download/application-notes/pdf/an-9012.pdf (open source s2).
- ROBOTERM, What is induction heating: exponential penetration, the eight-skin-depth diameter criterion, and copper skin-depth reference values at 40 °C. https://www.roboterm.cz/en/induction/about-induction/what-is-induction-heating (open source s4).
- Rudnev, Loveless and Cook, Handbook of Induction Heating, 2nd edition, CRC Press, 2017. https://doi.org/10.1201/9781315117485 — further reading on coupled electromagnetic and thermal heating; no licensed figures or tables reproduced.
- E. J. Davies, Conduction and Induction Heating, IEE Power Engineering Series 11, 1990. https://doi.org/10.1049/PBPO011E — further reading on workpiece impedance and heat transfer.
- L. A. Morley, Mine Power Systems, Volume I, U.S. Bureau of Mines, 1982, Table 3.2, printed p. 77: annealed copper resistivity and temperature coefficient. https://stacks.cdc.gov/view/cdc/235133
Inputs
| Input | Symbol | Unit | Default |
|---|---|---|---|
| Supply voltage | V_dc | V | 48 |
| Tank capacitance | C_t | uF | 2 |
| Capacitor bank ESR | R_cap | mohm | 1.5 |
| Capacitor design frequency | f_req | kHz | 100 |
| Work coil turns | N_c | 6 | |
| Coil inside diameter | D_in | mm | 40 |
| Winding length | l_coil | mm | 45 |
| Copper tube outside diameter | d_tube | mm | 6 |
| Copper tube wall thickness | wall_c | mm | 1 |
| Total lead length | l_lead | mm | 100 |
| Copper temperature | T_cu | °C | 40 |
| Coil proximity loss multiplier AC loss beyond isolated skin effect; use measured coil resistance when available. | F_prox | 2 | |
| Workpiece diameter | D_w | mm | 24 |
| Workpiece length | l_work | mm | 45 |
| Flux linkage adjustment Multiplies diameter and overlap estimates of coupling; calibrate against measured loaded inductance. | k_link | 0.85 | |
| Workpiece resistivity at 20 °C | rho_20 | uohm*m | 0.16 |
| Resistivity temperature coefficient | alpha_r | 1/K | 0.005 |
| Relative permeability below transition Use effective permeability at the actual field level; set 1 for nonmagnetic metals. | mu_cold | 70 | |
| Curie temperature | T_curie | °C | 770 |
| Curie transition width | dT_curie | K | 80 |
| Density | rho_mass | kg/m^3 | 7850 |
| Mean specific heat capacity Use the mean heat capacity over the intended temperature range. | c_heat | J/(kg*K) | 600 |
| Thermal conductivity | k_therm | W/(m*K) | 35 |
| Initial workpiece temperature | T_start | °C | 20 |
| Target temperature | T_goal | °C | 850 |
| Ambient temperature | T_air | °C | 20 |
| Convection coefficient | h_conv | W/(m^2*K) | 12 |
| Surface emissivity | emiss | 0.8 | |
| Heating simulation duration | t_max | s | 600 |
| Temperature sweep intervals | n_temp | 240 | |
| Elapsed heating time | t | s | 180 |
| Lead and stray inductance | L_stray | uH | 0.1 |
| Driver and feed efficiency allowance | eta_driver | 0.9 | |
| Uniform history intervals Adaptive time intervals are also subdivided to preserve sharp transients. | n_history | 1200 |
Results
With the default inputs above, the calc gives:
| Result | Value |
|---|---|
| Heating outcome | Target reached |
| Time to target / duration limit | 367.7 s |
| Temperature at elapsed time | 794.2 °C |
| Work coil inductance | 1.142 uH |
| Loaded inductance | 1.048 uH |
| Loaded resonant frequency | 109.9 kHz |
| Ideal bank for design frequency | 2.269 uF |
| Estimated coupling coefficient | 0.443 |
| Tank peak voltage | 150.8 V |
| Tank RMS voltage | 106.6 V |
| Coil RMS current | 147.3 A |
| Power into workpiece | 353.9 W |
| Copper loss | 207.4 W |
| Capacitor ESR loss | 32.5 W |
| Tank to workpiece efficiency | 0.596 |
| DC to workpiece efficiency | 0.536 |
| Estimated supply current | 13.7 A |
| Workpiece skin depth | 1.34 mm |
| Relative permeability | 1 |
| Workpiece resistivity | 0.7793 uohm·m |
| Convection and radiation loss | 291.5 W |
| Final temperature in simulation | 850 °C |
| Heated mass | 0.16 kg |
| Maximum bank RMS current | 147.3 A |
| Maximum bank reactive duty (kvar) | 15.7 kV·A |
| Minimum loaded tank Q | 17.9 |
| Maximum coil cooling load | 207.5 W |
Checked against sources
Each case below was calculated by this calc and agrees with the value from its source (within the tolerance where one is shown).
Nagaoka published 45° coefficient
Source: Nagaoka (1908), DOI 10.11429/ptmps1907.4.16_314, printed p. 325 / PDF p. 12, scanned table: α = 45°, coefficient 0.688423. Here mean diameter and length are both 46 mm, so α = atan(D/ℓ) = 45°. Value read from the original table image.
Inputs: Winding length = 46 mm; the others as above.
| Result | Source | This calc |
|---|---|---|
| Coil Nagaoka coefficient | 0.6884 | 0.6884 |
Published copper penetration at 10 kHz
Source: ROBOTERM, What is induction heating, copper at 40 °C: 10,000 Hz → 0.7 mm (rounded to 0.1 mm). The same page states 86.5% of heating lies within one skin depth in the high-skin limit. The tolerances follow the published rounding, not a fit of resistivity.
Inputs: Workpiece resistivity at 20 °C = 0.01724 uohm·m; Resistivity temperature coefficient = 0.00393 1/K; Relative permeability below transition = 1; Initial workpiece temperature = 40 °C; Target temperature = 100 °C; Capacitor design frequency = 10 kHz; the others as above.
| Result | Source | This calc |
|---|---|---|
| Skin depth at design frequency | 7 × 10⁻⁴ ± 5 × 10⁻⁵ m | 6.863 × 10⁻⁴ m |
| Fraction of high-skin heating within one skin depth | 0.865 ± 0.001 | 0.8647 |
Published copper penetration at 50 kHz
Source: ROBOTERM, What is induction heating, copper at 40 °C: 50,000 Hz → 0.3 mm. Absolute tolerance 0.05 mm reflects the source's one-decimal rounding.
Inputs: Workpiece resistivity at 20 °C = 0.01724 uohm·m; Resistivity temperature coefficient = 0.00393 1/K; Relative permeability below transition = 1; Initial workpiece temperature = 40 °C; Target temperature = 100 °C; Capacitor design frequency = 50 kHz; the others as above.
| Result | Source | This calc |
|---|---|---|
| Skin depth at design frequency | 3 × 10⁻⁴ ± 5 × 10⁻⁵ m | 3.069 × 10⁻⁴ m |