USB PD 3.1 EPR Cable Drop, Heating & Power Budget (48 V)

Calculate USB-C cable and connector voltage drop, I²R heating and delivered power at up to 48 V and 5 A. Compare current and constant-power loads.

#EPR #Joule heating #power budget #USB PD 3.1 #USB-C #voltage drop

A USB PD 3.1 EPR source can offer 48 V at 5 A, or 240 W at its port. The receiving device gets less power because the cable conductors and connector contacts dissipate heat. This USB-C voltage drop calculator separates those losses and shows the power budget that reaches the sink.

Engineers can use it to compare conductor sizes, investigate a warm connector, or check whether a downstream converter has enough input-voltage margin. Students can trace the same circuit through resistance, voltage drop, I²R heating and conservation of power.

Set up the power path

Enter the actual source-port voltage and negotiated current limit. For a nominal 48 V supply, also examine a lower source voltage such as 45.6 V when that tolerance applies. Set the receiving device's minimum operating voltage from its own requirements; this value is independent of the cable's USB drop limits.

Choose a specified load current or a constant power required at the sink port. A constant-power load draws additional current as its voltage falls. The calculator solves that interaction on the higher-voltage DC branch and flags requests without a solution or beyond the selected current limit.

Enter the one-way cable length. Each rail runs that distance. Estimate resistance from ideal copper AWG sizes and the number of equal parallel wires, or enter the aggregate resistance per length of each rail at 20 °C. For measured data, exclude connector resistance and normalize the wire resistance to that reference temperature. The assumed conductor temperature adjusts copper resistance; it is not a predicted temperature.

Each connector input represents all parallel contacts for one rail at one mated interface. The model includes two equal interfaces. For example, four equal 40 mΩ contacts in parallel have an equivalent resistance of 10 mΩ. Real current sharing, wear and contamination can make a single contact much hotter than the interface average.

Read the results

Sink voltage and delivered power describe the operating point. Total heating includes the cable and both interfaces; heat per metre includes conductors only. Connector heating is reported per end. Maximum sink power respects the selected current and device-voltage limits, without inferring a thermal rating.

The 5 A VBUS and ground drop margins separately screen the cable path against USB Type-C Release 2.5, March 2026, section 4.4.1. Positive margins cover only these modeled resistive drops. Additional VCONN return current is excluded. Check against the standard in force.

What this calculation does not cover

This is a steady DC model, not a PD protocol or compliance simulator. It assumes an EPR-capable source, sink and electronically marked cable with successful negotiation. It excludes inrush, disconnect arcing, protection timing, switching ripple, converter losses, unequal interfaces and thermal equilibrium. Watts of heating cannot be converted into a temperature rise without the actual thermal path and cooling conditions. Validate hot resistance, contact temperatures and device behavior on the intended assembly.

How it is calculated

The circuit equations are derived here from Ohm's law and conservation of energy. Each rail contains its one-way conductor resistance and two mated interfaces:

Rv=Lrv(T)+2RcvR_v=Lr_v(T)+2R_{cv}, Rg=Lrg(T)+2RcgR_g=Lr_g(T)+2R_{cg}, and Rloop=Rv+RgR_{loop}=R_v+R_g.

Copper uses r(T)=r20[1+α20(T−20 °C)]r(T)=r_{20}[1+\alpha_{20}(T-20\,°C)], with α20=0.00393 K−1\alpha_{20}=0.00393\,K^{-1} from NBS Handbook 100 (1966), PDF page 10. The AWG library provides ideal annealed-copper resistance at 20 °C; entered rail resistances include parallel wires before temperature correction.

For a specified current, Vsink=Vs−IRloopV_{sink}=V_s-IR_{loop} and Psink=IVsinkP_{sink}=IV_{sink}. Wire heat is I2(Rwv+Rwg)I^2(R_{wv}+R_{wg}); heat at each end is I2(Rcv+Rcg)I^2(R_{cv}+R_{cg}). Their sum equals VsI−PsinkV_sI-P_{sink}.

For constant sink power, the lower-current root is evaluated as I=2P/(Vs+Vs2−4RloopP)I=2P/(V_s+\sqrt{V_s^2-4R_{loop}P}). A negative discriminant has no DC solution. The power budget maximizes (Vs−IRloop)I(V_s-IR_{loop})I subject to I≤IlimitI\le I_{limit}, Vsink≥VminV_{sink}\ge V_{min} and the high-voltage branch I≤Vs/(2Rloop)I\le V_s/(2R_{loop}). Zero resistance is handled explicitly.

The separate 5 A drop screens follow USB Type-C Cable and Connector Specification Release 2.5 (March 2026), §4.4.1, PDF page 151: 0.50 V for VBUS and 0.25 V for ground, including both mated interfaces. These are cable-path screens, not overall compliance verdicts.

Assumptions

Two identical connector interfaces, one at each end; each rail input is the equivalent of all its parallel contacts. Contact resistances are supplied at operating temperature and receive no copper temperature correction. The default 10 mΩ per rail per interface is an illustrative scenario, not a manufacturer's typical value.

Cable conductors are annealed copper at a fixed, user-assumed temperature between 0 and 100 °C. AWG values describe ideal conductors; use measured or manufacturer resistance for stranded or plated copper. Non-copper conductors require a different temperature model and are outside this tool's scope. Equal parallel wires share current equally. No additional VCONN or auxiliary return current, active-cable electronics, source wiring or PCB resistance is included. A shield return is included only if represented in the entered ground equivalent.

The source is a fixed voltage at its port. The negotiated current limit must already account for the actual source and cable capabilities. Constant-power operation uses the high-voltage algebraic solution; this does not establish control-loop stability.

Where it applies

Applies to steady DC cable and contact loss calculations for a negotiated USB PD 3.1 EPR power path, with source voltage entered explicitly. Lower voltages are also accepted for comparison and reference-example verification. Cable-only transfer efficiency excludes source and sink converter losses; at zero load the displayed value is the limiting efficiency.

The power budget imposes electrical limits only. The 5 A drop screens omit VCONN return current and do not assess pin current sharing, allowable temperature rise, insulation, e-marker identity, protocol behavior or USB-IF certification. Temperature rise cannot be inferred from resistance or heat alone. Use measured thermal data and test the actual assembly. No disconnection, arcing, transient or short-circuit model is provided. Check against the standard in force; the cable drop screens here use Release 2.5, March 2026, reviewed 30 October 2026.

References

  • [USB-IF, USB Type-C Cable and Connector Specification, Release 2.5 (March 2026), §4.4.1 p. 151 and Appendix H p. 424](https://www.usb.org/document-library/usb-type-cr-cable-and-connector-specification-release-25). Attached source s4; no standard tables or figures are reproduced.
  • [NBS Handbook 100, Copper Wire Tables (1966), pp. 3–4; PDF pp. 9–10](https://nvlpubs.nist.gov/nistpubs/Legacy/hb/nbshandbook100.pdf). Attached source s3; copper resistance temperature coefficient.
  • [Texas Instruments, John Betten, SSZTBZ8, Power Tips: Don't Let a Drooping USB Voltage Slow Down Your Charger (October 2015), p. 1](https://www.ti.com/lit/pdf/ssztbz8). Independent 24 AWG cable/contact example.
  • [Analog Devices / Linear Technology, LT3697 data sheet 3697f, p. 14](https://www.analog.com/media/en/technical-documentation/data-sheets/3697f.pdf). Independent 0.2 Ω, 2.1 A cable-drop example.
  • [Texas Instruments, SSZTD49A (October 2024), USB Type-C and USB Power Delivery: Designing for both Extended Power Range and battery-powered systems](https://www.ti.com/document-viewer/lit/html/SSZTD49A/GUID-C6698731-EB4D-4238-8FE2-647CF1D2B970). EPR 48 V / 5 A context.

Inputs

InputSymbolUnitDefault
Source port voltage
Actual loaded source-port voltage; use 45.6 V to examine a −5% 48 V supply. PD negotiation is assumed complete.
V_sV48
Negotiated current limit
Use the smaller of source, cable and negotiated current capabilities; 5 A is the EPR ceiling.
I_limitA5
Device minimum input voltage
Your device's DC operating requirement. This is not a universal USB disconnect threshold.
V_minV45
Load modelload_modeSpecified current
Load currentI_setA5
Required power at sink port
Power at the receiving connector, before downstream converter losses. The high-voltage DC solution is used.
P_setW200
One-way cable length
Both VBUS and ground run this length. Do not enter twice the cable length. Zero isolates contact losses.
L_cm1
Conductor resistance datawire_modeIdeal copper AWG estimate
VBUS conductor gaugewire_vAWG 20
Parallel VBUS conductors
Number of equal wires sharing the VBUS current, not the number of plug contacts.
n_v1
Ground conductor gaugewire_gAWG 18
Parallel ground conductorsn_g1
VBUS rail resistance per length at 20 °C
Aggregate of all parallel VBUS wires, excluding both connectors. Normalize measured copper resistance to 20 °C first.
r_v20mohm/m33.3
Ground rail resistance per length at 20 °C
Aggregate return resistance, excluding both connectors. Include any real shield return contribution in this equivalent value.
r_g20mohm/m21
Assumed conductor temperature
An input to copper resistance correction, not a predicted cable temperature. The model does not solve thermal equilibrium.
T_wiredegC40
VBUS resistance per mated interface
Equivalent resistance of all parallel VBUS contacts at one cable end, at operating temperature. Both ends are assumed equal. Default is an illustrative 10 mΩ, not a part rating.
R_cvmohm10
Ground resistance per mated interface
Equivalent resistance of all parallel ground contacts at one end. Do not enter a single-pin resistance without accounting for parallel pins. Both ends are assumed equal.
R_cgmohm10

Results

With the default inputs above, the calc gives:

ResultValue
Sink port voltage47.507 V
Delivered sink power237.54 W
Operating current5 A
Total cable and connector heat2.463 W
Heat at each connector interface0.5 W
Cable conductor heating per length1.463 W/m
Maximum sink power within selected limits237.54 W
Sink power headroom0 W
Device voltage margin2.507 V
Cable transfer efficiency (%)98.97
VBUS drop margin at 5 A0.22 V
Ground drop margin at 5 A, without VCONN0.037 V

Checked against sources

Each case below was calculated by this calc and agrees with the value from its source (within the tolerance where one is shown).

TI: 1 m 24 AWG cable with four 30 mΩ interfaces

Source: TI SSZTBZ8 (October 2015), p. 1, https://www.ti.com/lit/pdf/ssztbz8 . The published example gives 0.166 Ω wire plus 0.12 Ω contacts, total 0.286 Ω, and approximately 0.6 V drop at 2.1 A. The AWG library uses 84.22 mΩ/m rather than the example's rounded 83 mΩ/m, giving 0.28844 Ω and 0.605724 V; 1% tolerance accommodates that stated approximation. This older USB example verifies DC physics, not EPR compliance.

Inputs: Source port voltage = 5 V; Device minimum input voltage = 4 V; Load current = 2.1 A; VBUS conductor gauge = AWG 24; Ground conductor gauge = AWG 24; Assumed conductor temperature = 20 °C; VBUS resistance per mated interface = 30 mohm; Ground resistance per mated interface = 30 mohm; the others as above.

ResultSourceThis calc
Total outgoing and return resistance0.286 ± 0.01 Ω0.2884 Ω
Total cable and connector voltage drop0.6 ± 0.01 V0.6057 V
Sink port voltage4.4 ± 0.01 V4.394 V

Analog Devices: 0.2 Ω cable at 2.1 A gives 0.42 V

Source: Analog Devices / Linear Technology, LT3697 data sheet 3697f, p. 14, https://www.analog.com/media/en/technical-documentation/data-sheets/3697f.pdf . Published compensation example: 0.2 Ω wire, 2.1 A, 0.42 V at 25 °C. This test freezes resistance at the cited 0.2 Ω by neutralizing temperature correction (reference temperature input 20 °C); its artificial equal rail split checks total IR drop only, not the source cable's construction or temperature coefficient.

Inputs: Source port voltage = 5 V; Device minimum input voltage = 4 V; Load current = 2.1 A; Conductor resistance data = Enter each rail's resistance at 20 °C; VBUS rail resistance per length at 20 °C = 100 mohm/m; Ground rail resistance per length at 20 °C = 100 mohm/m; Assumed conductor temperature = 20 °C; VBUS resistance per mated interface = 0 mohm; Ground resistance per mated interface = 0 mohm; the others as above.

ResultSourceThis calc
Total cable and connector voltage drop0.42 V0.42 V

USB Type-C 2.5: 48 V low-source sink example

Source: USB Type-C Cable and Connector Specification Release 2.5 (March 2026), Appendix H, p. 424. The published EPR example uses a source at 95% of 48 V and a 0.75 V total cable drop at 5 A, giving 44.85 V at the sink. Equivalent wire resistances reproduce that boundary; this test does not validate the appendix's arcing model.

Inputs: Source port voltage = 45.6 V; Device minimum input voltage = 44 V; Conductor resistance data = Enter each rail's resistance at 20 °C; VBUS rail resistance per length at 20 °C = 100 mohm/m; Ground rail resistance per length at 20 °C = 50 mohm/m; Assumed conductor temperature = 20 °C; VBUS resistance per mated interface = 0 mohm; Ground resistance per mated interface = 0 mohm; the others as above.

ResultSourceThis calc
Sink port voltage44.85 V44.85 V